Plan Review Notes
Plan Review Notes For Permit 06011238
Permit Number 06011238
Review Stop B
Sequence Number 3
Notes
Date Text
2006-10-23 15:07:07BUILDING REVIEW THIRD CHECKLIST:
 1-NEED RECORDED NOTICE OF COMMENCEMENT.
  
 2-AFTER ORIGINAL PLANS ARE REVISED BY THE ENGINEER,
 BRING THEM TO PALM BEACH COUNTY (2300 N JOG ROD) TO PAY
 IMPACT FEES. BRING BACK STAMPED DRAWINGS AND COPY OF
 PAID RECEIPT.
  
 3-MASTER BEDROOM EGRESS WINDOW 3'-0" X 6'-0" DOESN'T
 FIT IN THAT CORNER.WALL IS ONLY 3'-7. REVISE AS
 REQUIRED.
  
 4- PROVIDE PRODUCT APPROVAL FOR 5'-0" X 6'-0" SINGLE
 HUNG WINDOWS AS SPECIFIED ON PLANS. ALSO, SEE WINDOW
 PRODUCT APPROVAL FOR CORRECT WINDOW SIZES. WINDOW SIZES
 SPECIFIED ON PLANS ARE NOT FOUND IN THE PRODUCT
 APPROVAL SIZE CHART. REVISE AS REQUIRED.
  
 5-STORM SHUTTERS:
 A)ENGINEER CAN'T SIGN AND SEAL PRODUCT APPROVAL.
 ENGINEER WAS ASKED TO REVIEW AND APPROVE IN WRITTING
 (EG: TYPICAL REVIEW STAMP) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 B) THERE ARE TWO DIFFERENT DRAWINGS SUBMITTED. POMA
 AND WEATHERGUARD BUILDING PRODUCTS. PROVIDE COMPLETE
 AND LEGIBLE PRODUCT APPROVAL FOR ONLY ONE COMPANY.
  
 6-FLAT ROOF PRODUCT APPROVAL:
 A) ENGINEER TO REVIEW AND APPROVE PRODUCT APPROVAL.
 DON'T SIGN AND SEAL IT.
  
 B)ASSEMBLY SUBMITTED IS FOR TILE UNDERLAYMENT.
 ENGINEER CALLS FOR NON-INSULATED ASSEMBLY ON PAGE 24.
 BUT, NOA 03-0501.02 PAGE 24 IS FOR INSULATED ASSEMBLY.
 COORDINATE ALL INFORMATION AND RESUBMIT COMPLETE
 PRODUCT APPROVAL.
  
 C)ENGINEER TO USE EFFECTIVE WIND AREA OF 10S.F.
 FOR COMPONENT AND CLADDING WIND LOADS WHEN DETERMINING
 THE FASTENER SPACING FOR FLAT ROOF BASE SHEET. SEE ASCE
 7-02FIGURE 6-3 NOTE #4 AND TABLE ON PAGE 45. REVISE
 CALCULATIONS AS REQUIRED OR USE NUMBERS DIRECTLY FROM
 THE TABLE.THEN REVISE RAS 117 CALCULATIONS AND
 PROPOSED NAIL SPACING.
  
 D) ENGINEER TO CLARIFY IF PROPOSED NAIL SPACING FOR
 ZONE 3 IS THREEROWS TOTAL OR ONE ROW AT THE SIDE LAP
 AND THEN THREE ROWS EQUALLY SPACED IN THE FIELD OF THE
 SHEET.
  
 7-PROVIDE PRODUCT APPROVAL FOR:
 A)ALL SIMPSON STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS.
  
 B)FIXED WINDOW.
  
 C)CONCRETE LINTELS.
  
 8- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITTING
 (NOT SIGN AND SEAL)ALL PRODUCT APPROVALS AS REQUIRED
 BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 9-DRAWING #1:
 A) SECTION 2/A1 AND FOUNDATION PLAN DON'T MATCH. ONE
 SHOWS STEM WALL FOOTING AND THE OTHER SHOWS MONOLITHIC
 FOOTING. REVISE AS REQUIRED.
  
 B)FOUNDATION PLAN SHOWS EXISTING FINISH FLOOR SLAB
 INMASTER BEDROOM AT 9.14" AND MAIN HOUSE AT 16.14".
 CLARIFY WHY THE DIFFERENCE AND THERE ARE NO STEPS FROM
 ONE ROOM TO THE OTHER? REVISE AS REQUIRED.
  
 10- DRAWING #3: CLARIFY WHAT'S THE DIFFERENCE BETWEEN
 BEAMS B-1 AND B-2. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 11-PROVIDE ENERGY CALCULATIONS AS REQUIRED BY CHAPTER
 13 FBC 2004.
  
 12-DRAWING #7:
 A) R-30 INSULATION DOESN'T FIT IN 2X8 ROOF JOIST.
 REVISE AS REQUIRED.
 B) WALL SECTION 2/A7: REVISE HUS26 CONNECTOR AT
 MASONRY WALL. NEED TO SPECIFY MASONRY CONNECTOR. HUS26
 IS A WOOD TO WOOD CONNECTOR. SEE CURRENT CATALOGUE AND
 REVISE AS REQUIRED.
  
 13-PLEASE MAKE SURE ALL DRAWINGS ARE CLEAR AND
 LEGIBLE. SOME DRAWINGS ARE TOO LIGHT AND BLURRY.
  
 14- ENGINEER WILL BE REQUIRED TO PAY REVIEW FEES AS
 REQUIRED BY FLORIDA STATUTE 553.80(2)(B). SEE ATTACHED
 COPY.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712