| Date |
Text |
| 2007-02-16 09:08:57 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | |
| | THIRD REVIEW. FROM PREVIOUS REVIEWS: |
| | |
| | FROM PREVIOUS REVIEW: COMMENT NUMBER TO |
| | REMAIN THE SAME. |
| | |
| | 9. SHT A-2 SUBMIT CALCULATIONS FOR THE |
| | PRIMARY AND SECONDARY ROOF DRAINS PER |
| | SECTION 1106 & 1107 WITH ALL |
| | SUBSECTIONS. SHOW THE SF AREA OF THE |
| | ROOF, WITH 1/2 AREA OF ALL VERTICAL |
| | WALLS INCLUDING PARAPETS ADDED TO THE SF |
| | OF THE ROOF AS WELL AS THE AREA OF ALL |
| | ROOFS THAT DRAIN ONTO THE ROOF FROM |
| | ABOVE, (IF ANY). |
| | ***RESPONSE NOTED, BUT CALCULATIONS |
| | INDICATE A TOTAL OF 2,545SF. SHT A-1 |
| | INDICATES NEW RETAIL 2,640SF. ALSO NO |
| | INFORMATION FOR THE VERTICAL WALLS |
| | ADJACENT TO THE ROOF FROM THE OTHER |
| | SPACES IN THE BUILDING. NORTH ELEVATION |
| | ON SHT A-2 INDICATES THE TOP OF THE |
| | PARAPET TO BE 29'0", AND THE TOP OF THE |
| | PARAPET TO THE SOUTH IS 16'0". NO |
| | CONTRIBUTION FROM THE VERTICAL WALLS WAS |
| | INDICATED IN THE CALCULATIONS. ALSO |
| | PLEASE INDICATE THE ELEVATION FOR THE |
| | ROOF AT BOTH THE HIGH END AND THE LOW |
| | END TO VERIFY CALCULATIONS. |
| | ******NO RESPONSE, NOT ADDRESSED. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-7631 |
| | E-MAIL [email protected] |