| Date |
Text |
| 2007-07-20 09:21:04 | |
| | |
| | WE ASKED EXPLANATION FOR COMMENTS FOR REV 2, DATED |
| | 2/2/07. THE PERSON WHO RESPONDED COMMENTS FOR REV 2, |
| | DID NOT MENTIONED HIS/HER NAME ON THE COMMENTS SHEET. |
| | HE/SHE SAID "NO CHANGES" FROM PREVIOUS REVISION " THIS |
| | IS A SHELL ONLY" |
| | IF THIS PERMIT FOR A SHELL ONLY THENYOU STILL NEED TO |
| | SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT |
| | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE |
| | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & |
| | PARTICLES. |
| | |
| | |
| | BUT WE NEED THE FOLLOWING INFORMATIONFOR THIS PROJECT |
| | SITE IN ONE OF THE PERMITS YOU APPLIED(WHAT PERMIT # I |
| | CAN FIND THE FOLLOWING INFO): |
| | |
| | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). |
| | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR |
| | NOI. |
| | YOU CAN GET NOI INFO FROM |
| | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ |
| | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), |
| | EFFECTIVE MAY 1, 2003 |
| | 2. PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & |
| | ITS ENCLOSURE & ITS DETAILSPER CITY OF WPB, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , |
| | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, |
| | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST |
| | FLOOR ELEVATION, MUST MEET THESE MINIMUM REQUIREMENTS. |
| | PLEASE SHOW IN YOUR STORM WATER CALS. |
| | 4. MAKE SURE THESE SITE AREAS SHOWN ON DRAWINGS MUST |
| | MATCH WITH AREAS USED IN STORM WATER QUALITY |
| | CALCULATIONS. |
| | 5. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES |
| | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM |
| | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL |
| | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, ETC ON DRAWINGS, DO YOU HAVE EXFILTRATION |
| | TRENCHES. PLEASE SHOW DRY DETENTION/WET DETENTION AREAS |
| | WITH 100% FILL OF STORM WATER ELEVATION? |
| | 6. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST AROUND |
| | YOUR SITE. |
| | 7. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, A COPY OF |
| | GEO-TECH REPORT AND A LATESTEST COPY OF STORM STORM |
| | WATER QUALITY CALCULATIONS THAT YOU PROVIDED AT 45TH |
| | STREET. |
| | 8. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION |
| | DETAILS,CLOTHES USED FOR SILT ETC., PLANS SHOWING SILT |
| | FENCE AROUND THE SITE & CATCH BASINS.HEIGHT OF FENCE |
| | SHOULD BE HIGH ENOUGH PER FDEP TO STOP DUST & |
| | PARTICLES. |
| | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED 10. |
| | PLEASE PROVIDE LATEST COPY OF SET OF CIVIL DRAWINGS |
| | THAT WERE APPROVED AT 45TH STREET IN JUNE 2007. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |