| Plan Review Notes For Permit 06011055 |
| Permit Number |
06011055 |
|
| Review Stop |
FIRE |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2006-08-23 00:00:00 | ***DENIED*** | | | | | | PLEASE NOTE THAT THE FIRST REVIEW WAS | | | PASSED, HOWEVER COMMENTS WERE PROVIDED | | | THAT HAVE NOT BEEN ACKNOWLEDGED. PLEASE | | | SEE THE FOLLOWING WITH SOME ADDITIONS. | | | | | | 1) DUCT SMOKE DETECTORS ARE REQUIRED TO | | | BE EQUIPED WITH OCCUPANT NOTIFICATION | | | DEVICES NEAR UNIT. | | | | | | 2) RAMPS SHALL HAVE HANDRAILS ON BOTH | | | SIDES. | | | | | | 3) IF BUILDING IS SET BACK AT DISTANCE | | | GREATER THAN 150' FROM MAIN ROAD, FIRE | | | LANES WILL BE REQUIRED. | | | | | | 4) AN ADDRESS IS REQUIRED ON BUILDING TO | | | BE AT LEAST 6" IN HEIGHT AND CONTRASTING | | | TO THE BACKGROUND. PLEASE ILLUSTRATE ON | | | ELEVATIONS. | | | | | | 5) PLEASE INDICATE THE LOCATIONS OF 2A | | | 10B,C RATED FIRE EXTINGUISHERS. | | | | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | | FIRE PLAN REVIEW (561) 805-6722 |
|