| 2006-08-07 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 0611055 |
| | ADD: 2924 AUSTRALIAN AVE. |
| | CONT: WOLFF & CO |
| | TEL: (561)968-0484 EXT 0 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1STREVIEW |
| | ACTION: DENIED |
| | |
| | 1) WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE & REPLACE |
| | ANY PAGES AS NECESSARY. A TRANSMITTAL |
| | LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUM- BER, WITH A DESCRIPTION OF |
| | THE REVISION MADE, IDENTIFYING THE SHEET |
| | OR SPECIFICA TION PAGE WHERE THE CHANGES |
| | CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) FL S S 713.13 |
| | NOTICE OF COMMENCEMENT, TO BE FILED |
| | WITH THE CLERK OF THE COURT BEFORE A |
| | PERMIT WILL BE ISSUED. NOTE: 713.13(2) |
| | IF THE WORK DESCRIBED IN THE NOTICE OF COMMENCEMENT IS |
| | NOT ACTUALLY COMMENCED |
| | WITHIN 90 DAYS AFTER THE RECORDING |
| | THEREOF, SUCH NOTICE IS NULL & VOID. |
| | |
| | 3)PROVISO: 109.3.10* IMPACT OF |
| | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY |
| | REGULATED BY THIS CODE SHALL BE |
| | PERMORMED IN A MANNER SO AS NOT TO |
| | ADVERSLY IMPACT THE CONDITION |
| | OF ADJACENT PROPERTY, UNLESS SUCH |
| | ACTIVITY IS PERMITTED TO AFFECT SAID |
| | PROPERTY PURSUANT TO A CONSENT BY THE |
| | APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS |
| | AGREEABLE TO THE APPLICABLE |
| | PROPERTY OWNER.THIS INCLUDES BUT IS NOT |
| | LIMITED TO THE CONTROL OF DUST, NOISE, |
| | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND |
| | THE STORAGE OF CONSTRUCTION MATERIALS. |
| | NEW CONSTRUCTION ACTIVITY SHALL NOT |
| | ADVERSELY IMPACT HISTORICSURFACE WATER |
| | DRAINAGE FLOWS SERVING ADJACENT |
| | PROPERTIES, & MAY REQUIRE SPECIAL |
| | DRAINAGE DESIGNCOMPLYING WITH |
| | ENGINEERING STANDARDS TO PRESERVE THE |
| | POSITIVE PATTERNS OF THE AFFECTED SITES.ACCORDINGLY, |
| | DEVELOPERS, |
| | CONTRACTORS, AND OWNERS OF ALL NEW |
| | RESIDENTIAL DEVELOPMENET, INCLUDING |
| | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, |
| | DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIES RESULTING IN A DECREASE IN |
| | EXCESS OF 800SQ FT OF PERMEABLE LAND |
| | AREA ON ANY PARCELL SHALL AS A PERMIT |
| | CONDITION, PROVIDE A PROFESSIONALY |
| | PREPARED DRAINAGE PLAN CLEARLY |
| | INDICATING COMPLIANCE WITH THIS |
| | PARAGRAPH. UPON COMPLETION OF THE |
| | IMPROVEMENT, A CERTIFICATE FROM A |
| | LICENSED ENGINEER SHALL BE SUBMITTED TO |
| | THE INSPECTOR IN ORDER TO RECEIVE |
| | APPROVAL OF THE FINAL INSPECTION. |
| | |
| | 4) PROVISO: 109.3.10.1 HURICANE |
| | PROTECTION. IT SHALL BE UNLAWFUL FOR ANY |
| | PERSON TO ALLOW CONSTRUCTION RELATED |
| | MATERIALS EQUIPMENET AND DEBRIS TO |
| | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION |
| | SITE FROM 24 HRS. AFTER A |
| | HURRICANE WATCH HAS BEEN ISSUED UNTIL |
| | THE HURRICANE WATCH OR WARNING HAS BEEN |
| | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, |
| | EQUIPMENT AND DEBRIS SHALL BE EITHER |
| | REMOVED FROM THE CONSTRUCTION SITE OR |
| | SECURED IN SUCH A MANNER AS TO MINIMIZE |
| | THE DANGER OF SUCH CONSTRUCTION |
| | MATERIALS, EQUIPMENT AND DEBRIS CAUSING |
| | DAMAGE TO PERSONS OR PROPERTY FROM |
| | HIGHWINDS. |
| | ANY PERSONS WHO FAILS TO COMPLY TO |
| | REMOVE OR SECURE THE CONSTRUCTION |
| | MATERIALS EQUIPMENT AND DEBRIS WITHIN |
| | 24 HRS AFTER A HURRICANE WATCH HAS BEEN |
| | ISSUED SHALL BE SUBJECT TO A FINE NOT TO |
| | EXCEED $500.00. |
| | IN ADDITION TO THE ABOVE, A LICENSED |
| | CONTRACTOR WHO VIOLATES THIS SECTION |
| | SHALL BE SUBJECT TO DISCIPLINE PURSUANT |
| | TO SECTION 113 OF THIS CHAPTER. |
| | |
| | 5) COMPLIED. |
| | |
| | 6) 2ND REQUEST, |
| | W P B ADMINISTRTIVE CODE 106.3.3* |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH |
| | ARE REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. |
| | |
| | 7) 2ND REQUEST,DEPENDING ON THE PRODUCT |
| | APPROVALS THE CONTRACTOR SUBMITTED |
| | OR IF OTHER PRODUCTS WILL BE SUBSTITUTED |
| | FROM THE ORIGINAL SUBMITTAL. |
| | 1609.1.4 PROTECTION OF OPENINGS. |
| | IN WIND-BORNE DEBRIS REGIONS, EXTERIOR |
| | GLAZING THAT RECEIVES POSITIVE PRESSURE |
| | IN THE LOWER 60 FEET (18.3 M) IN |
| | BUILDINGS SHALL BE ASSUMED TO BE |
| | OPENINGS AND THE BALANCE OF GLAZED |
| | OPENINGS IN THE REST OF THE BUILDING |
| | SHALL BE ASSUMED TO BE ZERO UNLESS SUCH |
| | GLAZING THAT RECEIVES POSITIVE PRESSURE |
| | IS IMPACT RESISTANT OR PROTECTED WITH AN |
| | IMPACT RESISTANT COVERING MEETING THE |
| | REQUIREMENTS OF SSTD 12, ASTM E 1886 AND |
| | ASTM E 1996, OR MIAMI-DADE TAS 201, 202 |
| | AND 203 REFERENCED THEREIN AS FOLLOWS: |
| | 1.GLAZED OPENINGS LOCATED WITHIN 30 |
| | FEET (9.1 M) OF GRADE SHALL MEET THE |
| | REQUIREMENTS OF THE LARGE MISSILE TEST. |
| | 2.GLAZED OPENINGS LOCATED MORE THAN |
| | 30 FEET (9.1 M) ABOVE GRADE SHALL MEET |
| | THE PROVISIONS OF THE SMALL MISSILE |
| | TEST. |
| | |
| | 8) 2ND REQUEST, PRODUCT APPROVALS |
| | SUBMITTED WITH PERMIT APPLICATION AFTER |
| | OCTOBER 1, 2003 ARE REQUIRED TO COMPLY |
| | WITH THE FLORIDA PRODUCT APPROVAL |
| | SYSTEM. FOR INFORMATION PLEASE SEE THE |
| | STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 9) 2ND REQUEST, AGAIN DEPENDING ON THE |
| | CONTRACTORS NEXT SUBMITTAL THESE ARE THE |
| | |
| | REPORTS REQUIRED BY RULE 9B-72WITH |
| | FLORIDA COVER SHEET. |
| | A) FIXED GLASS |
| | B) STOREFRONT/ MULLIONS |
| | C) GLAZED DOORS |
| | D) EXT HOLLOW METAL DOORS |
| | E) OVERHEAD DOORS |
| | F)TRUSS ANCHORS |
| | G)ROOF ASSEMBLIES |
| | H) STORM SHUTTERS |
| | |
| | 10) 2ND REQUEST, |
| | FL BLD CODE 1804.2.2 QUESTIONABLE |
| | SOILS, WHERE THE BEARING CAPACITY IS |
| | NOT DEFINETLY KNOWN OR IS IN QUESTION. |
| | WHERE THE BEARING CAPACITY OF THE SOIL |
| | IS NOT DEFINITLY KNOWN OR IS IN QUESTION |
| | THE BUILDING OFFICIAL MAY REQUIRE EXPLOR |
| | ATIONS, TEST OR OTHER ADEQUATE PROOF AS |
| | TO THE PERMISSIBLE SAFE BEARING |
| | CAPACITY. REQUIRED TEST AND RECOMMENDA- |
| | TIONS SUBMITTED TO VERIFY BEARING CAPA- |
| | CITY SHALL BE CERTIFIED BY A GEOTECH- |
| | NICALREPORT FROM A DESIGN PROFESSIONAL |
| | PROPERLY LICENSED IN THE STATE OF |
| | FLORIDA. |
| | |
| | 11A) COMPLIED. |
| | |
| | 11B) CONCRETE, PROVIDE THE EDITION OF |
| | ACI 318 LISTED IN CHAPTER 35 2004 FBC. |
| | |
| | 11C) COMPLIED. |
| | |
| | 11D) 2ND REQUEST, THE SAME NOTE |
| | REGAURDING HIGH RIB LATH NAILING INTO |
| | FRAMING: ASTM C-1063 7.10.2.3. |
| | EXPANDED 3/8" RIB LATH AND SHEET |
| | EXPANDED METAL LATH SHALL BE ATTACHED TO HORIZONTAL AND |
| | VERTICAL WOOD SUPPORTS |
| | WITH NAILS OR STAPLES TO PROVIDE AT |
| | LEAST 1 3/4" PENETRATION INTO HORIZONTAL |
| | WOOD SUPPORTS AND 3/4" PENETRATION INTO |
| | VERTICAL WOOD SUPPORTS. |
| | |
| | 11E) COMPLIED. |
| | |
| | 12A & B) BOTH DEAL WITH THE ICENENE |
| | INSULATION. SHEET A-10 DETAIL# 2 |
| | INDICATES A EXTERIOR BLOCK WALL WITH A |
| | R=4.2 FOIL INSULATION TO THE CEILING |
| | HEIGTH. THIS IS TO BE A COMPLETE |
| | INSULATION PACKAGE TO THE UNDERSIDE OF |
| | THE ROOF, MISSING INSULATION ABOVE THE |
| | CEILING ON THE BLOCK WALL. |
| | |
| | THE SECOND ISSUE WITH THE ICENENE |
| | INSULATION IS THE REQUIREMENTS SET UP BY |
| | THE PALMBEACHCOUNTY BUILDING CODE |
| | ADVISORY BOARD FOR ALTERNATE MATERIALS |
| | AND METHODS. SEE ATTACHMENT. SEE |
| | REQUIREMENT 2 AND 3. REQUIREMENT# 2 WAS |
| | DISCUSSED IN THE PARAGRAPH ABOVE. |
| | |
| | THE THIRD ISSUE WILL BE TO GET A |
| | AFFIDAVIT FROM THE ROOFING MATERIAL / |
| | SYSTEMS MANUFACTURER, WHO SHALL PROVIDE |
| | AN AFFIDAVIT CERTIFYING USE OF THEIR |
| | PRODUCT OVER AN UNVENTED ATTIC SYSTEM. (NOTIRIZED). |
| | |
| | 13) 2ND REQUEST, PLANS INDICATE VARIOUS |
| | TYPE OF TRUSS ANCHORS. THE PLANS |
| | INDICATE THE MANUFACTURER TO BE SIMPSON, |
| | BUT THE MODEL NUMBERS ARE USP. THE |
| | RESPONCE LETTER STATES USP. PLEASE |
| | CHANGE THE PLANS TO THE CORRECT |
| | MANUFACTURER. |
| | |
| | 14) COMPLIED. |
| | |
| | 15) 2ND REQUEST, |
| | BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |