Plan Review Notes
Plan Review Notes For Permit 06010952
Permit Number 06010952
Review Stop B
Sequence Number 3
Notes
Date Text
2006-06-02 00:00:00 
 1) 11-4.1.3 (10) DRINKING FOUNTAINS .
 (A) WHERE ONLY ONE DRINKING FOUNTAIN
 IS PROVIDED ON A FLOOR, THERE SHALL BE A
 DRINKING FOUNTAIN WHICH IS ACCESSIBLE TO
 INDIVIDUALS WHO USE WHEELCHAIRS IN
 ACCORDANCE WITH SECTION 11-4.15 AND ONE
 ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY
 BENDING OR STOOPING. (THIS CAN BE
 ACCOMMODATED BY THE USE OF A ?HI-LO?
 FOUNTAIN; BY PROVIDING ONE FOUNTAIN
 ACCESSIBLE TO THOSE WHO USE WHEELCHAIRS
 AND ONE FOUNTAIN AT A STANDARD HEIGHT
 CONVENIENT FOR THOSE WHO HAVE DIFFICULTY
 BENDING; BY PROVIDING A FOUNTAIN
 ACCESSIBLE UNDER SECTION 11-4.15 AND A
 WATER COOLER; OR BY SUCH OTHER MEANS AS
 WOULD ACHIEVE THE REQUIRED ACCESSIBILITY
 FOR EACH GROUP ON EACH FLOOR.)
  
 2) 11-4.1.6 ACCESSIBLE BUILDINGS:
 ALTERATIONS
 (B) IF EXISTING ELEMENTS, SPACES, OR
 COMMON AREAS ARE ALTERED, THEN EACH SUCH
 ALTERED ELEMENT, SPACE, FEATURE, OR AREA
 SHALL COMPLY WITH THE APPLICABLE
 PROVISIONS OF SECTION 11-4.1.1 TO
 SECTION 11-4.1.3 , MINIMUM REQUIREMENTS
 FOR NEW CONSTRUCTION.
 NOTE: A MINIMUM OF 60" IS REQUIRED FORM
 THE TOILET STALL WALL TO THE EDGE OF THE
 LAVATORY. SEE FIG.30E FOR MORE
 INFORMATION. ALSO INDICATE THE CLEAR
 FLOOR SPACE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  
  
  