| 2006-03-18 00:00:00 | |
| | PAUL SCHMITZ |
| | [email protected] |
| | FBC 2004 PLUMBING CODE PLAN REVIEW |
| | FBC2004 FUEL GAS CODEPLAN REVIEW |
| | FBC 2004 CH 11, FL ACESSIBILITY CODE |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPT.1, ADMINISTRATION, 2004 EDITION |
| | DENIED |
| | 1) SHT 2.1 PROJECT DATA ( ASSEMBLY) |
| | PLEASE CLARIFI, PLANS SHOW, BUSINESS AND |
| | WARE HOUSE OCCUPANCY. |
| | SHOW LOCATION OF STUDIO AND SEATING. |
| | THE USE OF OXYGEN TANK HOLDING AREA, |
| | AND RESPITORY THERAPIST ROOM. |
| | 2) SHT C.1 DESIGN SYMBOLS. |
| | SHOW THE SYMBOL FOR WALLS TO BE REMOVED |
| | OR RELOCATED IN THE KITCHEN. |
| | |
| | 3) SEC 403 MINIMUM FACILITIES |
| | ONE DRINKING FOUNTAIN REQUIRED. |
| | |
| | 4)SHT 2.1 MEN AND WOMENS REST RM |
| | SEC 11-4.17.3 SIZE AND ARRANGEMENT |
| | EXCEPTION: NEW CONSTRUCTION. |
| | (1) THE STANDARD ACCESSIBLE RESTROOM |
| | STALL SHALL CONTAIN AN ACCESSIBLE |
| | LAVATORY WITHIN IT, THE SIZE OF SUCH |
| | LAVATORY TO BE NOT LESS THAN 19 INCHES |
| | WIDE BY 17 INCHES (483 MM BY 432 MM) |
| | DEEP, NOMINAL SIZE, AND WALL MOUNTED. |
| | THE LAVATORY SHALL BE MOUNTED SO AS NOT |
| | TO OVERLAP THE CLEAR FLOOR SPACE AREAS |
| | REQUIRED BY SECTION 11-4.17 [SEE FIGURE |
| | 11-30(A) AND FIGURE 11-30(E)] AND TO |
| | COMPLY WITH SECTION 11-4.19 OF THE CODE. |
| | SUCH LAVATORIES SHALL BE COUNTED AS PART |
| | OF THE REQUIRED FIXTURE COUNT FOR THE |
| | BUILDING. |
| | (5) THE ACCESSIBLE WATER CLOSET SHALL BE |
| | LOCATED IN THE CORNER, DIAGONAL TO THE |
| | DOOR. |
| | |
| | END OF COMMENTS, QUESTIONS 561-805-6692 |