| Date |
Text |
| 2006-08-05 00:00:00 | DENIED |
| | REFERENCE: FBC-2004 PLUMBING |
| | FBC-2004 CHAPTER 1 |
| | FBC-2004 CHAPTER 11 |
| | |
| | 1. SHT T1.1 CODE INDICATED IS FBC-2001, |
| | CODE ADOPTED IS FBC-2004. PLEASE CHANGE |
| | REFERENCE TO PROPER CODE. |
| | ****RESPONSE NOTED, BUT SOME REFERENCES |
| | TO FBC-2001 STILL ON PLANS. |
| | |
| | 2. OK |
| | |
| | 3. SHT A1.2 DETAIL #4 BREAK ELEVATION: |
| | SINK SHALL BE ACCESSIBLE. SUBMIT |
| | INFORMATION SHOWING COMPLIANCE WITH |
| | SECTION 11-4.24 AND ALL SUBSECTIONS. |
| | CLEAR FLOOR SPACE SHALL BE FORWARD |
| | APPROACH AND NO CABINET DOORS ALLOWED IN |
| | THE CLEAR FLOOR SPACE. |
| | ****RESPONSE NOTED, BUT DETAIL SHOW |
| | 120'-0" OPENING. PLEASE CLARIFY. - ALSO |
| | SHOW THE FOLLING INFORMATION: |
| | A. 11-4.24.3 KNEE CLEARANCE |
| | B. 11-4.24.4 SINK DEPTH |
| | C. 11-4.24.6 EXPOSED PIPES & SURFACES |
| | D. 11-4.24.7 FAUCETS |
| | |
| | 4. OK |
| | 5. OK |
| | 6. OK |
| | 7. OK |
| | 8. OK |
| | |
| | 7. SUBMIT A WATER RISER DIAGRAM IN |
| | ISOMETRIC FORM SHOWING ALL PIPE SIZES, |
| | VALVES, WATER HAMMER ARRESTORS REQUIRED |
| | BY SECTION 604.9. IF INSTALLED ARRESTORS |
| | SHALL BE LOCATED NEAR THE FIXTURE IN AN |
| | "EFFECTIVE RANGE" NOT IN THE CEILING. |
| | SECTION 106.3.5.1.3. |
| | ****RESPONSE NOTED, BUT FULL OPEN VALVES |
| | ARE REQUIRED AT THE TOP OF EVERY WATER |
| | DOWN-FEED PIPE PER SECTION 606.1(4). |
| | PLEASE SHOW ON RISER DIAGRAM. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 805-6731 |
| | E-MAIL [email protected] |