| Plan Review Notes For Permit 06010618 |
| Permit Number |
06010618 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-02-02 00:00:00 | DENIED | | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | AND FBC-2004 RES. R4101 SWIMMING POOLS | | | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | | SUBMITTALS TO REFLECT THE FOLLOWING | | | INFORMATION REQUIRED FOR PLAN REVIEW: | | | | | | 1) COMPLY WITH FBC-2004 SEC 424.2 AND | | | FBC-2004 RES. R4101 PRIVATE SWIMMING | | | POOLS. (ADD TO NOTES) | | | 2) FBC-2001424.2.6.6.5 AND FBC-2004 | | | RES. R4101.6.6.5 | | | WHERE PROVIDED, THE VACUUM OR PRESSURE | | | CLEANER FITTING SHALL BE LOCATED AT | | | LEAST 6" AND NOT GREATER THAN 12" BELOW | | | THE MINIMUM OPERATING WATER LEVEL OR | | | AS AN ATTACHMENT TO THE SKIMMER. (ADD TO | | | NOTES AND GIVE DETAILS) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX (561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)805-6721 |
|