Plan Review Notes
Plan Review Notes For Permit 06010605
Permit Number 06010605
Review Stop P
Sequence Number 1
Notes
Date Text
2006-01-30 00:00:00DENIED;
 1.CHANGE PLUMBING NOTES NUMBER ONE TO
 READ THE 2004 CODES.
 2.W/M DRAIN TO BE 3" FBC-2004 PLUMBING
 SEC. 406.3.
 3.PLEASE SHOW DRAINAGE FROM FLAT ROOFS.
 SEE FBC-2004 CHAPTER 11. INCLUDE SCUPPER
 SIZES LOCATIONS AND GUTTERS AND DOWN
 SPOUTS.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695