Plan Review Notes
Plan Review Notes For Permit 06010504
Permit Number 06010504
Review Stop B
Sequence Number 1
Notes
Date Text
2006-05-11 00:00:00 
  
 DENIED
  
 1) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC* PERMIT VALUE WILL BE ADJUSTED
 ACCORDINGLY
  
 2) WIND DESIGN INFORMATION SHT A3 SHALL
 USE ASCE 7-02 STANDARD FROM 2004 FBC
 ALSO DRAWING SPECIFIES EXP. C AND THE
 COMPONENT AND CLADDING SHT IS USING 2001
 CODE WITH EXP. B PLEASE CLARIFY
  
 3) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT
 APPLICATION OR BEFORE INSTALLATION
  
 4) THE PERMIT APPLICATION SHALL INCLUDE
 TWO COPIES OF EACH PRODUCT APPROVAL THAT
  
 IS RELEVANT PER 9B-72. THESE SHOULD
 INCLUDE THE FLORIDA STATE APPROVAL COVER
 PAGES, AND THE PRODUCT NOA THAT LISTS
 THE SYSTEM COMPONENTS/ FASTENER LIST
 PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE
 GENERAL LIMITATIONS PAGE. ALL CAN BE
 FOUND ON WWW.FLORIDABUILDING.ORG
  
 5) THOSE PRODUCTS WHICH ARE REGULATED BY
 DCA RULE 9B-72 SHALL BE REVIEWED AND
 APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 6) PRODUCT APPROVAL FOR SINGLE HUNG
 WINDOWS DO NOT STATE DESIGN PRESSURES.
 THESE ARE REQUIRED FOR PRODUCT
 COMPLIANCE, PLEASE PROVIDE MANUFACTURERS
  
 SPECIFICATIONS FOR DESIGN PRESSURES ON
 THIS PRODUCT. ALSO SUPPLY THE SIZE OF
 THE MANUFACTURERS SH DESIGNATIONS (SH23,
 SH24, SH25, AND SH35)
  
 7) MIN. FOOTING DEPTH BELOW GRADE IS 12"
 PER 1805.2 FBC, DETAIL K/8 ON A8 SHOW
 10" ALSO FOUNDATION SCHEDULE FOR TYPE 1
 FOUNDATION DOES NOT MATCH SIZE ON DETAIL
 K/8 ON A8 PLEASE CLARIFY
  
 8) SECTION L/8 ON A8 HAS TWO DIFFERENT
 CEILING HEIGHTS PLEASE CLARIFY
  
 9) SEE PLACEMENT OF ATTIC ACCESS ON A5
 THIS LOCATION WILL NOT PROVIDEREQUIRED
 30" CLEARANCE ABOVE
  
 10) ATTIC ACCESS DETAIL D/3 ONA3 DOES
 NOT MEET THE MIN. WIDTH REQUIREMENT OF
 20"
  
 11) PROVIDE BEAM/LINTEL SCHEDULE WITH
 LENGTHS THAT MEET THE 4" MIN. BEARING
 PER 2104.1.5
  
 12) PROVIDE DRAINAGE PLAN (SHOW DRAINAGE
 ON SITE OR LANDSCAPE PLAN)
  
 13) ENERGY CALC'S SHALL BE SIGNED BY
 OWNER/AGENT
  
 14) FEE SIMPLE TOWNHOUSES REQUIRE
 SEPERATE PROPERTY CONTROL NUMBERS
  
 15) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  