| Date |
Text |
| 2006-04-18 00:00:00 | ****CORRECTIONS**** |
| | ****PLAN CHECK ONLY**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2.)DOCUMENTS PREPARED BY AN ARCHITECT |
| | AND SUBMITTED FOR PUBLIC RECORD ARE TO |
| | BE SIGNED, SEALED, AND DATED ORIGINALS |
| | FAC61G1-16.003 (REDUCED SITE PLAN). |
| | |
| | 3.)GOVERNING CODE IS FBC2004, FBC 2004 |
| | EXISTING BUILDING CODE (NOT FBC2001) |
| | EFFECTIVE OCTOBER, 2005. |
| | |
| | 4.)DECLARE CONSTRUCTION TYPE IN |
| | ACCORDANCE WITH FBC CHAPTER 3. |
| | |
| | 5.)IT IS NOT CLEAR HOW YOU HAVE |
| | DETERMINED THE OCCUPANT LOAD.ASSEMBLY |
| | WITHOUT FIXED SEATS, UNCONCENTRATED, IS |
| | 15 NET FBC TABLE 1004.1.2.WITHOUT |
| | ALLOWANCES FOR KITCHEN SPACE, WALLS, |
| | ETC. THE TOTAL BASED ON GROSS SQUARE |
| | FOOT AREA SHOULD BE 519.CLARIFY HOW |
| | YOU HAVE DETERMINED OCCUPANT LOAD.SEE |
| | FBC 1004.1. |
| | |
| | 6.)PARKING IS TO COMPLY WITH CITY OF |
| | WEST PALM BEACH STANDARD.SEE ATTACHED |
| | AND SEE ZONING PROVISO ON THE PLAN. |
| | |
| | 7.)A SEPARATE PERMIT WILL BE REQUIRED |
| | FOR THE DUMPSTER ENCLOSURE FOR TRACKING |
| | PURPOSES.WHEN SUBMITTING A PERMIT |
| | APPLICATION, ALSO COMPLETE AN |
| | APPLICATION FOR THE DUMPSTER ENCLOSURE. |
| | SEPARATE PLANS ARE NOT REQUIRED. |
| | |
| | 8.)THIS COMMENT IS NOT REQUIRED TO BE |
| | ADDRESSED AS THE DOOR IS EXISTING. |
| | DOORS 3 LACK THE MANEUVERING CLEARANCE, |
| | PULL SIDE, FBC11-4.13.6, FBC11 FIGURE |
| | 25.DINING 8 AND DINING 4. |
| | |
| | 9.)DECLARE LEVEL OF ALTERATION, FBC EB |
| | 3. |
| | |
| | 10.)PROVIDE WIND DESIGN INFORMATION |
| | FBC1603.1.4. |
| | |
| | 11.)PRODUCT APPROVALS REQUIRED FOR |
| | COMPONENTS AND CLADDING.FLORIDA STATE |
| | OR LOCAL PRODUCT APPROVAL REQUIRED, |
| | FAC9B72. |
| | |
| | 12.)USE OF REMOVABLE SHUTTERS ON |
| | COMMERCIAL BUILDINGS MUST BE APPROVED BY |
| | THE BUILDING OFFICIAL.IF THIS IS YOUR |
| | INTENT, PLEASE CONTACT ME FOR THE |
| | PROCEDURE TO SUBMIT A MISSILE IMPACT |
| | PROTECTION INSTALLATION PLAN. |
| | RESUBMITTAL OF THE PLAN SHOWING |
| | REMOVABLE SHUTTERS WITHOUT ADDRESSING |
| | THIS ITEM WILL RESULT IN DELAYS IN |
| | PERMIT ISSUANCE. |
| | |