2006-03-29 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06010433 (FOUNDATION NO SLAB)
 ADD: 419 LAKEVIEW
 CONT: MICHAEL T. LANG
 TEL(561)966-5592
  
  
 -OPERA PLACE-
  
 ARCHITECT FIRM BERMELLO, AJAMIL &
 PARTNERS
 HECTOR R. VALVERDE
  
 ENGINEERS: PEDRO JOSE DUQUESNE
  
  
 1ST REVIEW
 ACTION DENIED
 CODE: 2004 FL BUILDING CODE
  
 * FL BLD CODE = 2004 WEST PALM BEACH
 ADMINISTRATIVE CODE
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE NEW
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 1) NOTE THIS IS A THRESHOLD BUILDING
 REQUIRING (3) OF ALL SUBMITTALS,
 PLANS, REPORTS, REVISIONS OR SUBMITTALS
 TO THE BUILDING DEPARTMENT FOR OUR
 RECORD. THESE DOCUMENTS WILL REQUIRE
 ORIGINALS WITH RAISED SEAL, SIGNATURE
 AND DATE.
 PLANS, SPECIFICATIONS,REPORT OR
 OTHER DOCUMENTS PREPARED BY THE
 PROFESSIONAL AND BEING FILED FOR PUBLIC
 RECORD SHALL HAVE THE SIGNATURE
 SEAL OF THE DESIGN PROFESSIONAL
 TO THE DOCUMENT.
 FL STATE STAT: 61G15-23.002 ENGINEER
 FL ATATE STAT: 61G16.003 ARCHITECT
 ONLY (1) SET OF THE SOILS REPORTS
 ARE SEALED. THE OTHER (2) SETS ARE
 COPIED SIGNATURES , NO SEALS.
  
 2)FL S S 713.13:
 NOTICE OF COMMENCEMENT, TO BE RECORDED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE:
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) DISCREPANCY BETWEEN THE PERMIT
 APPLICATION AND THE SURVEY. THE
 APPLICATION INDICATES THE STREET
 LAKEVIEW WHEREAS THE SURVEY IN
 THE SOUTH SIDE OF THE PROPERTY
 OKEECHOBEE BLVD. OKEECHOBEE BLVD ISN'T
 DESIGNATED UNTIL AFTER THE WEST BOUND
 TRAFFIC CROSSES OVER THE FEC RAILROAD
 TRACKS.
  
 4) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 5) FL S. S. 553.71(7)
 (THRESHOLD BUILDING)
 ANY BUILDING GREATER THAN (3) STORIES OR
 50 FEET IN HEIGHT, OR WHICH HAS AN
 ASSEMBLY OCCUPANCY CLASSIFICATION AS
 DENIED IN FLORIDA BUILDING CODE WHICH
 EXCEEDS 5,000 SQ FT IN AREA AND AN
 OCCUPANT LOAD OF GREATER THAN 500 PEOPLE
 105.13.1 THE ENFORCING AGENCY SHALL
 REQUIRE A SPECIAL INSPECTOR TO PERFORM
 STRUCTURAL INSPECTIONS ON A THRESHOLD
 BUILDING PURSUANT TO A STRUCTURAL
 INSPECTION PLAN PREPARED BY THE ENGINEER
 OF RECORD. THE STRUCTURAL INSPECTION
 PLAN MUST BE SUBMITTED TO THE
 ENFORCEMENT AGENCY PRIOR TO THE ISSUANCE
 OF A PERMIT FOR THE CONSTRUCTION OF
 THRESHOLD BUILDING. THE PURPOSE OF THE
 STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND
 STANDARDS SO THAT THE BUILDING CAN BE
 ADEQUATELY INSPECTED FOR COMPLIANCE WITH
 THE PERMITTED DOCUMENTS.
  
 6)WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A
 SPECIAL INSPECTOR AS REQUIRED BY S.
 553.79(5) FLORIDA STATUTES TO THE MIN-
 IMUM INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT HAROLD PISKURA MANAGER OF THE
 SPECIAL INSPECTOR PROGRAM AT (561)
 805-6711 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 7) W.P.B. AMENDMENT 105.13.4.4 ALL PLANS
 FOR THE BUILDING WHICH ARE REQUIRED TO
 BE SIGNED AND SEALED BY THE ARCHITECT OR
 ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR
 ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTE.
  
 8) 109.3.10* IMPACT OF CONSTRUCTION.
 ALL CONSTRUCTION ACTIVITY REGULATED BY
 THIS CODE SHALL BE PERFORMED IN A MANNER
 SO AS NOT TO ADVERSELY IMPACT THE
 CONDITION OF ADJACENT PROPERTY, UNLESS
 SUCH ACTIVITY IS PERMITTED TO AFFECT
 SAID PROPERTY PURSUANT TO A CONSENT BY
 THE APPLICABLE PROPERTY OWNER, UNDER
 TERMS & CONDITIONS AGREEABLE TO THE
 APPLICABLE PROPERTY OWNER. THIS INCLUDES
 BUT IS NOT LIMITED TO THE CONTROL OF
 DUST, NOISE, WATER OR DRAINAGE RUN-OFF,
 DEBRIS, AND THE STORAGE OF CONSTRUCTION
 MATERIALS. NEW CONSTRUCTION ACTIVITY
 SHALL NOT ADVERSELY IMPACT
 HISTORIC SURFACE WATER DRAINAGE FLOWS
 SERVING ADJACENT PROPERTIES, & MAY
 REQUIRE SPECIAL DRAINAGE DESIGN
 COMPLYING WITH ENGINEERING STANDARDS TO
 PRESERVE THE POSITIVE PATTERNS OF THE
 AFFECTED SITES. ACCORDINGLY, DEVELOPERS,
 CONTRACTORS, AND OWNERS OF ALL NEW
 RESIDENTIAL DEVELOPMENT, INCLUDING
 ADDITIONS, POOLS, PATIOS, DRIVEWAYS,
 DECKS, OR SIMILAR ITEMS, ON EXISTING
 PROPERTIES RESULTING IN A DECREASE IN
 EXCESS OF 800SQ FT OF PERMEABLE LAND
 AREA ON ANY PARCEL SHALL AS A PERMIT
 CONDITION, PROVIDE A PROFESSIONALLY
 PREPARED DRAINAGE PLAN CLEARLY
 INDICATING COMPLIANCE WITH THIS
 PARAGRAPH. UPON COMPLETION OF THE
 IMPROVEMENT, A CERTIFICATE FROM A
 LICENSED ENGINEER SHALL BE SUBMITTED TO
 THE INSPECTOR IN ORDER TO RECEIVE
 APPROVAL OF THE FINAL INSPECTION.
  
 9) 109.3.10.1 HURRICANE PROTECTION.
 IT SHALL BE UNLAWFUL FOR ANY PERSON TO
 ALLOW CONSTRUCTION RELATED MATERIALS
 EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR
 OTHERWISE UNSECURED AT A CONSTRUCTION
 SITE FROM 24 HRS. AFTER A HURRICANE
 WATCH HAS BEEN ISSUED UNTIL THE
 HURRICANE WATCH OR WARNING HAS BEEN
 LIFTED. ALL SUCH CONSTRUCTION MATERIALS,
 EQUIPMENT AND DEBRIS SHALL BE EITHER
 REMOVED FROM THE CONSTRUCTION SITE OR
 SECURED IN SUCH A MANNER AS TO MINIMIZE
 THE DANGER OF SUCH CONSTRUCTION
 MATERIALS, EQUIPMENT AND DEBRIS CAUSING
 DAMAGE TO PERSONS OR PROPERTY FROM
 HIGH WINDS.
 ANY PERSON WHO FAILS TO COMPLY TO
 REMOVE OR SECURE THE CONSTRUCTION
 MATERIALS EQUIPMENT AND DEBRIS WITHIN
 24 HRS AFTER A HURRICANE WATCH HAS BEEN
 ISSUED SHALL BE SUBJECT TO A FINE NOT TO
 EXCEED $500.00.
 IN ADDITION TO THE ABOVE, A LICENSED
 CONTRACTOR WHO VIOLATES THIS SECTION
 SHALL BE SUBJECT TO DISCIPLINE PURSUANT
 TO SECTION 113 OF THIS CHAPTER.
  
 10) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OF THE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601. A OR B.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
  
 11) PLANS INDICATE THAT THIS PERMIT
 WILL BE PHASED, DOES THIS MEAN
 ENTIRE BUILDING IS UNDER ONE PERMIT OR
 WILL THIS PROJECT BE PERMITTED
 SEPARATELY ?
  
 12) SHEET S-3.00
 WIND DESIGN LOADS, DESIGNED TO THE WRONG
 ASCE STANARD ASCE 7-02
  
 13) SHEET S-3.00
 WIND DESIGN LOADS, FOR PARKING PORTION
 OF THE BUILDING AS BEING DESIGNED TO THE
 2001 FBC NOT THE 2004 FBCAND ALSO
 DESIGNED TO THE ASCE 7-98 STANDARD.
  
 14) SHEET S-3.00
 FOUNDATION NOTE # 5 INDICATES THE PILE
 LENGTH FROM TIP ELEVATION OF -65 FT
 WHEREAS THE SOILS REPORT 8.2.2 PILE
 DESIGN RECOMMENDATIONS INDICATES 50 FT.
 THE SOILS REPORT PILE DESIGN
 RECOMMENDATIONS INDICATES THAT
 APPROXIMATELY 42 FT THE AUGER PILE WILL
 ENCOUNTER HARD LIMESTONE STRATUM AND DIG
 UNTIL 50 FT. THE -65 FT DEPTH WILL MEAN
 THE AUGER PILE WILL BE ENBEDDED
 APPROXIMATELY 23 FT?
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  
  
  
2006-03-06 00:00:00ZONING REVIEWED - CAN MAKE NO
 DETERMINATION; NO SITE PLAN OR ARCH PLAN
 PROVIDED TO VERIFY SETBACKS AND BUILDING
 PLACEMENT. MJF