2006-02-02 00:00:00BUILDING REVIEW THIRD CHECKLIST:
 1- SAME COMMENT FROM SECOND CHECKLIST:
 SELECTED FLAT ROOF SYSTEM IS LIMITED TO
 A MAXIMUM DESIGN PRESSURE OF -45PSF AND
 BY GENERAL LIMITATION #9, WHICH DOESN'T
 ALLOW ADDITIONAL NAIL ENHANCING TO
 INCREASE THE DESIGN PRESSURES.
  
 2- A) ENGINEERED CALCULATIONS SUBMITTED
 ARE NOT ALLOWED BECAUSE OF GENERAL
 LIMITATION #9 OF ROOF ASSEMBLY SELECTED.
 ENGINEERED CALCULATIONS CAN ONLY BE
 PROVIDED WHEN GENERAL LIMITATION #7
 APPLIES.
  
 B) ENGINEER TO CLEARLY IDENTIFY EXACT
 ROOF ASSEMBLY THAT IS REFERENCED IN THE
 PRODUCT APPROVAL WHEN SUBMITTING THE
 CALCULATIONS.
  