| 2006-05-05 00:00:00 | |
| | |
| | DENIED |
| | |
| | NOTES 1 AND 4 WHERE ADDRESSED BUT MORE |
| | INFORMATION IS NEED, NOTE 3 WAS NOT |
| | ADDRESSED. |
| | |
| | 1) HANDRAIL EXTENTION IS SHOWN ON A2-1.0 |
| | BUT SIZE IS NOT SHOWN. PLEASE SHOW THAT |
| | MIN REQUIREMENT IS MET PER 11-4.8.5(2) |
| | FBC |
| | A2-1.0 SHOWS FOOTING UNDER CMU.THERE ARE |
| | NO DETAILS FOR FOOTING ONTHIS DETAIL OR |
| | 03/A0-0 |
| | LANDINGS ON RAMPS ARE REQUIRED TO BE NO |
| | LESS THAN 72" PER 11-4.8.4(2) FBC |
| | |
| | 3) PLEASE SEE A1-1.0 AT DOOR 114 AND |
| | RAMP MANUVERING REQUIRES A MINIMUM 24" |
| | OF LEVEL AREA ON THE LATCH SIDE ALSO |
| | APPROCH FROM THE PUSH SIDE REQUIRES A |
| | MINIMUM 12" AT THE LATCH SIDE OF DOOR |
| | (SEE FIG. 25 (A)AND(B) IN CHAPTER 11) |
| | FBC |
| | |
| | 4) IN BUILDINGS WITH MULTIPLE ACCESSIBLE |
| | ENTRANCES, ACCESSIBLE PARKING SPACES |
| | SHALL BE DISPERSED AND LOCATED CLOSEST |
| | TO THE ACCESSABLE ENTRANCES PER 11-4.6.2 |
| | FBC |
| | |
| | NEW NOTES: |
| | |
| | 1) DOOR 114 IS AN INTERIOR DOOR THAT |
| | WILL BE USED AS AN EXTERIOR DOORAS |
| | SUCH PLEASE PROVIDE PRODUCT APPROVALS |
| | PER 9B-72 F.A.C. ALSO STATE WIND DESIGN |
| | CRITERIA AND COMPONENT AND CLADING PSF"S |
| | FOR DOOR ON DRAWING PER 1603.1.4 FBC |
| | |
| | 2) APPLICABLE CODES SECTION OF PAGE T1 |
| | AND LS0-0 DO NOT MATCH SHOULD READ FBC |
| | 2004 PLEASE CLARIFY |
| | |
| | 3) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT IS REQUIRED PRIOR TO |
| | A PERMIT BEING ISSUED. ALTHOUGH IT IS |
| | GOOD FOR 1 YEAR FROM DATE OF ISSUE WORK |
| | MUST COMMENCE WITHIN 90 DAYS. PLEASE |
| | RE-RECORD |
| | |
| | 4) PLEASE NOTE THAT NO FURTHER PLAN |
| | REVIEWS WILL BE DONE UNTIL FALSE ALARM |
| | FEES ARE PAID AND FINANCE DEPT HOLD IS |
| | REMOVED CONTACT EFRAIM GARCED @ 805-1320 |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |