| Plan Review Notes For Permit 06010008 |
| Permit Number |
06010008 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2006-03-01 00:00:00 | DENIED 2ND TIME | | | REFERENCE:FBC-2004 424.2 SWIMMING POOLS | | | | | | PLEASE ADJUST YOUR NOTES, AND DETAILS TO | | | REFLECT THE FOLLOWING INFORMATION | | | REQUIRED FOR PLAN REVIEW: | | | | | | 1) FBC-2004424.2.6.6.5 WHERE PROVIDED, | | | THE VACUUM OR PRESSURE CLEANER FITTING | | | SHALL BE LOCATED AT LEAST 6" AND NOT | | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | | THE SKIMMER. (PLEASE ADD "OR AS AN | | | ATTACHMENT TO THE SKIMMER" AND PROVIDE | | | DETAILS) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561)805-6730 | | | FAX(561)805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561)6721 | | | |
|