2006-03-01 00:00:00DENIED 2ND TIME
 REFERENCE:FBC-2004 424.2 SWIMMING POOLS
  
 PLEASE ADJUST YOUR NOTES, AND DETAILS TO
 REFLECT THE FOLLOWING INFORMATION
 REQUIRED FOR PLAN REVIEW:
  
 1) FBC-2004424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER. (PLEASE ADD "OR AS AN
 ATTACHMENT TO THE SKIMMER" AND PROVIDE
 DETAILS)
  
 END OF COMMENTS:
  