| Plan Review Notes For Permit 05121217 |
| Permit Number |
05121217 |
|
| Review Stop |
B |
| Sequence Number |
18 |
|
| Notes |
| Date |
Text |
| 2007-11-07 10:11:19 | 2004 FBC | | | SUBMITTAL FOR ROOFING (LIGHTWEIGHT CONCRETE, MODIFIED | | | BITUMEN, RAS 117 CALCULATIONS) | | | | | | DENIED BY BUILDING | | | | | | 1) THE RAS 117 CALCULATIONS FROM ATLANTIC & CARIBBEAN | | | ROOF CONSULTING, LLC ARE REQUIRED TO BE SIGNED, SEALED | | | AND DATED BY THE ENGINEER. THE EMBOSSED SEAL AND | | | ORIGINAL SIGNATURES ARE REQUIRED. FS 741 AND FAC | | | 61G15-23.002 | | | | | | 2) THE ROOF COMPONENT AND CLADDING UPLIFT PRESSURES | | | SPECIFIED ON THE RAS 117 CALCULATIONS DO NOT CORRESPOND | | | WITH THE ROOF UPLIFT PRESSURES THAT ARE SPECIFIED ON | | | STRUCTURAL SHEET S-12 OF THE PLANS (-76.9, -120.6) AND | | | BOTH ARE FOR EXPOSURE CATEGORY 'C'. PLEASE CORRECT. | | | | | | - ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | [email protected] |
|