Plan Review Notes
Plan Review Notes For Permit 05121073
Permit Number 05121073
Review Stop E
Sequence Number 1
Notes
Date Text
2005-12-30 00:00:00******** UNSAT **********
  
  
 1)NOTE: PLEASE KNOW, THE RESERCH FOR THE
 MENTIONED ADDRESS HAS SHOWN REAR
 BUILDING BUILT AS A GARAGE AND A
 PRELIMINARY SERCH DOES NOT INDICATE A
 LEGAL CONVERSION. PLEASE CONTACT APRIL
 PICCIRILLO (805-6658) FOR A RESERCH
 REQUEST TO FIND OF ANY PERMITS HAVE BEEN
 PULLED FOR THE CONVERSION FROM A GARAGE
 TO A GUESTHOUSE/COTTAGE FROM 1962 TO THE
 PRESENT.
 PLEASE ALSO CONTACT ZONING TO FIND OUT
 OF UNIT IN REAR WOULD BE LEGAL.
  
 PLEASE KNOW THE ELECTRICAL PERMIT TO BE
 REVIEWED AND CLEARED ONCE THIS IS DONE.
 ** PLEASE SEE MINOR ELECTRICAL COMMENTS
 WHICH CAN BE REDLINED IF ZONING IS OK.
  
 1)>GROUNDING ELECTRODE SYSTEM AT THE
 DEATCHED BLDG. 250.32
 2)>ARC FAULT FOR BED RM AREA IN
 COTTAGE(IF PERMITTED).210.12
 3)> INDICATE THE MEANS OF DISCONNECT AT
 THE DETACHED BLDG. 225.31
 4)> SIZE OF PANEL AT DETACHED BLDG.(OCP
 SHOWS 60A FEED.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.\
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]