| Date |
Text |
| 2006-03-13 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | 1.)THE SCOPE OF WORK IS NOT CLEAR. |
| | THE APPLICATION STATES "EXPANSION", |
| | WHICH IMPLIES AN ADDITION, BUT A |
| | FOUNDATION PLAN IS NOT SHOWN.NO SITE |
| | PLAN WAS PROVIDED.THE PLANS STATE BOTH |
| | "EXIST CART BARN" AND "NEW LAUNDRY". |
| | |
| | 2.)ONLY A PARTIAL FLOOR PLAN WAS |
| | PROVIDED.WHAT IS IN THE REST OF THE |
| | BUILDING?DECLARE OCCUPANCY FOR THIS |
| | AREA AND ADJACENT AREA, ADDRESSING ANY |
| | FIRE RATING REQUIREMENTS, IF ANY.SHOW |
| | NEARBY STRUCTURES. |
| | |
| | 3.)THE SINGLE DOORAPPEARS TO LEAD |
| | OUTSIDE; IS THIS CORRECT?WHY DOES THE |
| | WALL THAT IT IS PERPENDICULAR TO EXTEND |
| | FURTHER, IMPLYING ADDITIONAL AREA?ALSO |
| | THIS DOOR IS FIRE RATED, IMPLYING A |
| | SEPARATION, AND THE DOUBLE DOOR DOES NOT |
| | SHOW A FIRE RATING.IF THIS DOOR LEADS |
| | TO INTERIOR SPACE, EVEN IF IT IS A WORK |
| | SPACE, THE DOOR MUST MEET MANEUVERING |
| | CLEARANCE FBC11-4.13.6. |
| | |
| | 4.)IF THIS IS AN ADDITION, PROVIDE A |
| | SITE PLAN.IMPACT FEES REQUIRED, |
| | 233-5025. |
| | |
| | 5.)IF THIS IS AN ADDITION, SHOW A WALL |
| | DETAIL CONTINUOUS FROM THE FOUNDATION |
| | THROUGH THE ROOF, ALL WIND DESIGN |
| | CRITERIA, FBC16. |
| | |
| | 6.)FLORIDA STATE OR LOCAL PRODUCT |
| | APPROVAL REQUIRED IN ADDITION TO THE |
| | NOAS PROVIDED, FAC9B72. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 7.)NOT ENOUGH INFORMATION TO |
| | DETERMINE CODE COMPLIANCE. |