| Plan Review Notes For Permit 05120828 |
| Permit Number |
05120828 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2006-02-01 00:00:00 | DENIED; | | | ELECTRICAL PLAN E-1 SHOWS A COFFEE SHOP | | | WITH A HAND SINK, ICE BIN, AND SMOOTHIE | | | BLENDERS. PLUMBING PLANS NEEDED FOR | | | REVIEW. PLANS SHOULD ALSO BE REVIEWED BY | | | DEPARTMENT OF HOTEL AND RESTAURANTS. HOT | | | WATER REQUIRED. A UTILITY SINK IS NEEDED | | | TO WASH EQUIPMENT @ BLENDERS, COFFEE | | | POTS. A MOP SINK IS ALSO REQUIRED BY | | | FBC-2004 PLUMBING TABLE 403.1. INDIRECT | | | WASTE RESEPTORES MAY BE REQUIRED FOR ICE | | | BIN AND COFFEE EQUIPMENT. PLEASE SHOW A | | | SANITARY AND WATER RISER DIAGRAMS SHOW | | | PIPE SIZES AND TIE IN LOCATIONS. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|