| Date |
Text |
| 2006-01-25 00:00:00 | |
| | |
| | |
| | DENIED |
| | |
| | 1) PEMIT VALUE IS LOW SHOULD INCLUDE |
| | LABOUR AND MATERIALS. BASED ON FAIR |
| | MARKET VALUE IN PUBLICATIONS SUCH AS |
| | MEANS OR MARSHALL & SWIFTS. VALUE SHOULD |
| | BE APPROX. $2450.00 |
| | |
| | 2) SPECIFY IF EXISTING 6X6 PORCH IS TO |
| | BE REMOVED OR IS IT TO BE ADDED ON TO |
| | |
| | 3) ALL ATTACHMENTS EG. PLATE TO STUDS, |
| | RAFTERS TO HEADER AND WALL, ETC. SHALL |
| | HAVE HURRICANE CONNECTORS/CLIPS. THESE |
| | SHALL BE STATED ON A SCHEDULE WITH THE |
| | PRODUCTS INFORMATION SUCH AS |
| | MANUFACTURER AND # EG. SIMPSON H10 |
| | |
| | 4) 2X6 PT PLATE ATTACHED WITH 5" |
| | REDHEADS, SPECIFY WHAT THE ON CENTER |
| | SPACING WILL BE |
| | |
| | 5) DOUBLE 2X8 HEADER THAT IS ATTACHED TO |
| | HOUSE SHALL ALSO PROVIDE ON CENTER |
| | ATTACHMENT SPACING, ALSO VERIFY THAT |
| | HOUSE IS MASONARY IF REDHEADS ARE TO BE |
| | USED |
| | |
| | 6) SUBMIT PRODUCT APPROVALS FOR ROOF |
| | MEMBRANE AND ROOF TILES. ROOF TILES ARE |
| | MORTARED DOWN TO THE MEMBRANE (USUALLY A |
| | MODIFIED BITUMEN PRODUCT) THAT PERFORMS |
| | THE WATER PROTECTION FOR THE ROOF |
| | |
| | 7) THE PERMIT APPLICATION SHALL INCLUDE |
| | TWO COPIES OF EACH PRODUCT APPROVAL PAGE |
| | THAT IS RELEVANT. THESE SHOULD INCLUDE |
| | THE FLORIDA STATE APPROVAL COVER PAGES, |
| | AND THE PRODUCT NOA THAT LISTS THE |
| | SYSTEM COMPONENTS/ FASTENER LIST PAGES, |
| | THE PAGES WITH THE CHOSEN ASSEMBLY/ |
| | SYSTEM TO BE USED AND THE GENERAL |
| | LIMITATIONS PAGE. ALL CAN BE FOUND ON |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | |
| | |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |