| 2006-01-24 00:00:00 | |
| | |
| | DENIED |
| | |
| | |
| | 1) DRAWINGS SHALL COMPLY WITH FBC 2004 |
| | AND THECITY OF WPB AMMENDMENTS |
| | |
| | 2) ADJUST VALUATION IT IS TO LOW FOR |
| | THIS WORK. VALUE SHOULD INCLUDE ALL |
| | LABOUR AND MATERIALS TO COMPLETE WORK. |
| | WE USE MARHALL AND SWIFT CONSTRUCTION |
| | VALUATION MANUAL THAT PUTS A VALUE CLOSE |
| | TO $18,000.00 FOR THIS WORK |
| | |
| | 3) ALL DRAWINGS AND SPECIFICATIONS SHALL |
| | BE SIGNED AND DATED BY THE PERSON |
| | RESPONSIBLE FOR THEM |
| | |
| | 4) SUBMIT 2 COPIES OF THE SITE PLAN WITH |
| | THE LOCATION OF THE PATIO AND GARAGE |
| | SHOWN, ALSO MARK IN ALL SETBACK |
| | MEASUREMENTS |
| | |
| | 5) SPECIFY IF GARAGE IS TO BE OPEN |
| | (CARPORT) OR WILL IT HAVE DOORS |
| | INSTALLED. IF DOORS ARE TO BE INSTALLED |
| | SUBMIT A BUCK ATTACHMENT DETAIL FOR BOTH |
| | OPENINGS |
| | |
| | 6) SPECIFY TYPE OF LUMBER AND GRADE TO |
| | BE USED FOR ROOF FRAMING MEMBERS ON |
| | GARAGE AND PATIO |
| | |
| | 7) SPECIFY SIZE OF REINFORCING STEEL IN |
| | BOND BEAM |
| | |
| | 8) VERIFY THAT EPOXY BOLT DETAIL 13 ON |
| | S1.2 IS INTO EXISTING TIE BEAM |
| | |
| | 9) SHOW ELEVATION DETAIL OF GARAGE |
| | OPENING TO CLARIFY BEAM ATTACHMENT AT |
| | BOTH EXISTING HOUSE AND NEW WALL |
| | |
| | 10) SPECIFY WALL FINISHES TO BE APPLIED |
| | TO CMU BLOCK WALLS EG. STUCCO, SIDING |
| | |
| | 11) ENGINEERING SHALL BE PROVIDED THAT |
| | VARIFIES THE LATERAL PRESSURES ON THE |
| | BEAM TO WALL CONNECTION ARE ACCEPTABLE |
| | AND THAT THE BEAM SPAN WILL WORK FOR |
| | GARAGE OPENING. ALSO THAT THE BEAM SPANS |
| | THAT CARRY THE PATIO ROOF JOISTS WILL |
| | WORK. |
| | |
| | 12) TERMITE PROTECTION SHALL BE PROVIDED |
| | PER SECTION 1816 FBC 2004 OR R320.1 FBC |
| | RES. PRIOR TO CONCRETE SLAB PLACEMENT |
| | |
| | 13) SUBMIT PRODUCT APPROVALS FOR ROOF |
| | COVERING AND IF NEEDED SWINGING DOOR AND |
| | GARAGE SECTIONAL DOOR |
| | |
| | 14) THE PERMIT APPLICATION SHALL INCLUDE |
| | TWO COPIES OF EACH PRODUCT APPROVAL PAGE |
| | THAT IS RELEVANT. THESE SHOULD INCLUDE |
| | THE FLORIDA STATE APPROVAL COVER PAGES, |
| | AND THE PRODUCT NOA THAT LISTS THE |
| | SYSTEM COMPONENTS/ FASTENER LIST PAGES, |
| | THE PAGES WITH THE CHOSEN ASSEMBLY/ |
| | SYSTEM TO BE USED AND THE GENERAL |
| | LIMITATIONS PAGE. ALL CAN BE FOUND ON |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 15) A RADON SURCHARGE FEE SHALL BE PAID |
| | FOR ALL UNDER ROOF FLOOR SPACE WHICH |
| | INCLUDES ATTACHED CARPORTS, GARAGES, |
| | PORCHES, UTILITY ROOMS AND STORAGE ROOMS |
| | |
| | |
| | BLDG PLAN REVIEW |
| | ADRIAN MORSE |
| | 561-805-6716 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |