Plan Review Notes
Plan Review Notes For Permit 05120429
Permit Number 05120429
Review Stop B
Sequence Number 27
Notes
Date Text
2009-10-26 13:50:07****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC EB FLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FAC FLORIDA ADMINISTRATIVE CODE
 FS FLORIDA STATUTE
  
 1. ALTHOUGH THE PLAN STATES THAT THE COMMON PATH OF
 TRAVEL IS 0, THIS SHOULD BE MEASURED TO THE POINT AT
 WHICH THE OCCUPANT HAS THE CHOICE OF TWO EXITS. AS
 THERE ARE NO EXITS ON ONE SIDE, THE OCCUPANT WOULD BE
 FORCED TO TRAVEL TOWARDS THE SIDE WITH EXITS, SO THIS
 IS THE DISTANCE WHICH SHOULD BE COUNTED AS COMMON PATH
 OF TRAVEL. PLEASE SEE THE COMMENTARY FOR A MORE
 THOROUGH EXPLANATION OF COMMON PATH OF TRAVEL. THE PLAN
 DECLARES THIS AREA AS F3, SEE FBC1013.3, THE COMMON
 PATH EXCEEDS THE MAXIMUM ALLOWED. PLEASE CLARIFY THE
 USE OF THIS AREA; IS THIS A PROCESSING AREA?
  
 I EMAILED THE CONTRACTOR ON 10/22 BUT HAVE NOT YET
 RECEIVED A RESPONSE. PLEASE CONTACT ME TO DISCUSS.


Account Summary | Usage Policy | Privacy Policy