| Date |
Text |
| 2006-02-14 00:00:00 | |
| | PLUMBING PLAN REVIEW EXAMINER |
| | PAUL SCHMITZ 561-805-6692 |
| | [email protected] |
| | FBC PLUMBING 2004 |
| | FBC FUEL GAS 2004 |
| | FBC 2004 BUILDING CH 11 |
| | DENIED |
| | 1)SHT A-1 BREAK ROOM SINKS |
| | 11-4.24.1 GENERAL. |
| | SINKS REQUIRED TO BE ACCESSIBLE BY |
| | SECTION 11-4.1 SHALL COMPLY WITH SECTION |
| | 11-4.24. |
| | 11-4.24.3 KNEE CLEARANCE. |
| | KNEE CLEARANCE THAT IS AT LEAST 27 |
| | INCHES (685 MM) HIGH, 30 INCHES (760 MM) |
| | WIDE, AND 19 INCHES (485 MM) DEEP SHALL |
| | BE PROVIDED UNDERNEATH SINKS. |
| | 11-4.24.4 DEPTH. |
| | EACH SINK SHALL BE A MAXIMUM OF 61/2 |
| | INCHES (165 MM) DEEP. |
| | 11-4.24.5 CLEAR FLOOR SPACE. |
| | A CLEAR FLOOR SPACE AT LEAST 30 INCHES |
| | BY 48 INCHES (760 MM BY 1219 MM) |
| | COMPLYING WITH SECTION 11-4.2.4 SHALL BE |
| | PROVIDED IN FRONT OF A SINK TO ALLOW |
| | FORWARD APPROACH. THE CLEAR FLOOR SPACE |
| | SHALL BE ON AN ACCESSIBLE ROUTE AND |
| | SHALL EXTEND A MAXIMUM OF 19 INCHES (485 |
| | MM) UNDERNEATH THE SINK (SEE FIGURE |
| | 11-32). |
| | 11-4.24.6 EXPOSED PIPES AND SURFACES. |
| | HOT WATER AND DRAIN PIPES EXPOSED UNDER |
| | SINKS SHALL BE INSULATED OR OTHERWISE |
| | CONFIGURED SO AS TO PROTECT AGAINST |
| | CONTACT. THERE SHALL BE NO SHARP OR |
| | ABRASIVE SURFACES UNDER SINKS. |
| | 11-4.24.7 FAUCETS. |
| | FAUCETS SHALL COMPLY WITH SECTION |
| | 11-4.27.4. LEVER-OPERATED, PUSH-TYPE, |
| | TOUCH-TYPE, OR ELECTRONICALLY CONTROLLED |
| | MECHANISMS ARE ACCEPTABLE DESIGNS. |
| | |
| | 2)SHT P1.01 TOILET ROOM SHOWER. |
| | 11-4.21.1 GENERAL. |
| | ACCESSIBLE SHOWER STALLS SHALL COMPLY |
| | WITH SECTION 11-4.21. |
| | 11-4.21.2 SIZE AND CLEARANCES. |
| | EXCEPT AS SPECIFIED IN SECTION 11-9.1.2, |
| | SHOWER STALL SIZE AND CLEAR FLOOR SPACE |
| | SHALL COMPLY WITH FIGURE 11-35(A) OR |
| | FIGURE 11-35(B). THE SHOWER STALL IN |
| | FIGURE 11-35(A) SHALL BE 36 INCHES BY 36 |
| | INCHES (915 MM BY 915 MM). |
| | 11-4.21.3 SEAT. |
| | A SEAT SHALL BE PROVIDED IN SHOWER |
| | STALLS 36 INCHES BY 36 INCHES (915 MM BY |
| | 915 MM) AND SHALL BE AS SHOWN IN FIGURE |
| | 11-36. THE SEAT SHALL BE MOUNTED 17 |
| | INCHES TO 19 INCHES (430 MM TO 485 MM) |
| | FROM THE BATHROOM FLOOR AND SHALL EXTEND |
| | THE FULL DEPTH OF THE STALL. IN A |
| | 36-INCH BY 36-INCH (915 MM BY 915 MM) |
| | SHOWER STALL, THE SEAT SHALL BE ON THE |
| | WALL OPPOSITE THE CONTROLS. IT SHALL BE |
| | A FOLDING TYPE AND SHALL BE MOUNTED ON |
| | THE WALL ADJACENT TO THE CONTROLS AS |
| | SHOWN IN FIGURE 11-57. THE STRUCTURAL |
| | STRENGTH OF SEATS AND THEIR ATTACHMENTS |
| | SHALL COMPLY WITH SECTION 11-4.26.3. |
| | 11-4.21.4 GRAB BARS. |
| | GRAB BARS COMPLYING WITH SECTION 11-4.26 |
| | SHALL BE PROVIDED AS SHOWN IN FIGURE |
| | 11-37. |
| | 11-4.21.5 CONTROLS. |
| | FAUCETS AND OTHER CONTROLS COMPLYING |
| | WITH SECTION 11-4.27.4 SHALL BE LOCATED |
| | AS SHOWN IN FIGURE 11-37. IN SHOWER |
| | STALLS 36 INCHES BY 36 INCHES (915 MM BY |
| | 915 MM), ALL CONTROLS, FAUCETS, AND THE |
| | SHOWER UNIT SHALL BE MOUNTED ON THE SIDE |
| | WALL OPPOSITE THE SEAT. |
| | 11-4.21.6 SHOWER UNIT. |
| | A SHOWER SPRAY UNIT WITH A HOSE AT LEAST |
| | 60 INCHES (1525 MM) LONG THAT CAN BE |
| | USED BOTH AS A FIXED SHOWER HEAD AND AS |
| | A HAND-HELD SHOWER SHALL BE PROVIDED. |
| | 11-4.21.7 CURBS. |
| | IF PROVIDED, CURBS IN SHOWER STALLS 36 |
| | INCHES BY 36 INCHES (915 MM BY 915 MM) |
| | SHALL BE NO HIGHER THAN ? INCH (13 MM). |
| | SHOWER STALLS THAT ARE 30 INCHES BY 60 |
| | INCHES (760 MM BY 1525 MM) MINIMUM SHALL |
| | NOT HAVE CURBS. |
| | 11-4.21.8 SHOWER ENCLOSURES. |
| | IF PROVIDED, ENCLOSURES FOR SHOWER |
| | STALLS SHALL NOT OBSTRUCT CONTROLS OR |
| | OBSTRUCT TRANSFER FROM WHEELCHAIRS ONTO |
| | SHOWER SEATS. |
| | |
| | 3) SHT P-1.01 |
| | CORRELATE DWV ISOMETRIC, WITH PLUMBING |
| | FIXTURE LAY OUT, MOP SINK SHOWN ON |
| | ISOMETRIC? |
| | |
| | 4)SHT P1.01 WATER HEATER,PROVIDE DETAIL |
| | 607.3 THERMAL EXPANSION CONTROL. |
| | A MEANS OF CONTROLLING INCREASED |
| | PRESSURE CAUSED BY THERMAL EXPANSION |
| | SHALL BE PROVIDED WHERE REQUIRED IN |
| | ACCORDANCE WITH SECTIONS 607.3.1 AND |
| | 607.3.2. |
| | 607.3.1 PRESSURE-REDUCING VALVE. |
| | FOR WATER SERVICE SYSTEM SIZES UP TO AND |
| | INCLUDING 2 INCHES (51 MM), A DEVICE FOR |
| | CONTROLLING PRESSURE SHALL BE INSTALLED |
| | WHERE, BECAUSE OF THERMAL EXPANSION, THE |
| | PRESSURE ON THE DOWNSTREAM SIDE OF A |
| | PRESSURE-REDUCING VALVE EXCEEDS THE |
| | PRESSURE-REDUCING VALVE SETTING. |
| | END OF COMMENTS, QUESTIONS 561-805-6692 |