2005-12-23 00:00:00DENIED;
 1.W/M TO DISCHARGE BELOW L/T, AND A C.O.
 TO BE INSTALLED AT 48" AFF.
 2.W/M BRANCH DRAIN SHALL BE 3" TO TO
 SAN. TEE.
 3.1/2 BATH NOT THE SAME LAY OUT AS FLOOR
 PLAN.
 4.SAOARATE RISERS ARE REQUIRED FOR
 SECOND FLOOR BATHROOMS. CAN NOT RUN INTO
 VENT STACKS FOR FIRST FLOOR FIXTURES.
 5. SHEET A-1 SHOWS 2 L/T'S RISER DIAGRAM
 SHOWS ONE, PLEASE CLARIFY.
 6.SECOND FLOOR BATHROOM #1 RISER DIAGRAM
 SHOWS 2 LAV'S FLOOR PLAN SHOWS ONE.
 PLEASE CLARIFY.