| 2005-12-01 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05111008 |
| | ADD: 4200 N FLAGLER DR |
| | CONT:CENTEX |
| | TEL: (561)2289-0276 |
| | FL BLD CODE= 2004 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PLANS NEED TO BE UPDATED TO THE 2004 |
| | FL BLDG CODE. THE FOLLOWING ITEMS NEED |
| | TO REFLECT THE REQUIREMENTS OF 110.2.* |
| | 1A) THE EDITION OF THE CODE UNDER WHICH |
| | THE PERMIT WAS ISSUED. |
| | 1B) THE USE AND OCCUPANCY, IN ACCORDANCE |
| | WITH THE PROVISIONS OF CHAPTER 3 . |
| | 1C) THE TYPE OF CONSTRUCTION AS DEFINED |
| | IN CHAPTER 6 . |
| | 1D)THE DESIGN OCCUPANT LOAD. |
| | 1E) IF AN AUTOMATIC SPRINKLER SYSTEM IS |
| | PROVIDED, WHETHER THE SPRINKLER SYSTEM |
| | IS REQUIRED. |
| | 1F) ANY SPECIAL STIPULATIONS AND |
| | CONDITIONS OF THE BUILDING PERMIT. |
| | |
| | 2) SEE TABLE 601 & 602 FOR NEW BLDG |
| | CLASSIFICATION, FIRE REISITANT |
| | REQUIREMENTS PLEASE CORRECT. |
| | |
| | 3) SEE TABLE 503 FOR ALLOWABLE HEIGHT & |
| | AREA. |
| | |
| | 4)UPDATE PLANS TO THE 2004 CODE FOR |
| | T803.3 SEE TABLE 803.5. |
| | 803.5 INTERIOR FINISH REQUIREMENTS BASED |
| | ON GROUP. |
| | INTERIOR WALL AND CEILING FINISH SHALL |
| | HAVE A FLAME SPREAD INDEX NOT GREATER |
| | THAN THAT SPECIFIED IN TABLE 803.5 FOR |
| | THE GROUP AND LOCATION DESIGNATED. |
| | INTERIOR WALL AND CEILING FINISH |
| | MATERIALS, OTHER THAN TEXTILES, TESTED |
| | IN ACCORDANCE WITH NFPA 286 AND MEETING |
| | THE ACCEPTANCE CRITERIA OF SECTION |
| | 803.2.1 , SHALL BE PERMITTED TO BE USED |
| | WHERE A CLASS A CLASSIFICATION IN |
| | ACCORDANCE WITH ASTM E 84 IS REQUIRED. |
| | TABLE 803.5 |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |