Plan Review Notes
Plan Review Notes For Permit 05110980
Permit Number 05110980
Review Stop B
Sequence Number 1
Notes
Date Text
2005-12-21 00:00:00 
  
 DENIED
  
 1) SPECIFY THE VALLEY TRUSS TIE DOWN
 CONNECTOR TO MEET THE UPLIFT VALUES
 STATED ON THE TRUSS PLAN
  
 2) WIND LOAD PROVISIONS TO THE 2004 FBC
 ARE IN SECTION 1609 NOT 1606 AS
 SPECIFIED
  
 3) THE VENT SCREENS FROM DRAWING
 X-SECTION ARE NOW UNDER SECTION 1203.2
 OF THE FBC. THEIR ARE SOME CHANGES TO
 THIS SECTION
  
 4) SPECIFY ATTIC ACCESS SIZE TO MEET
 1209.2 FBC.
  
 5) CONSRTUCTION DOCUMENTS SHALL SHOW
 ROOF & FLOOR LIVE LOADS PER 1603.1 FBC
  
 6) 2 COPIES OF THE STATE OF FLORIDA
 PRODUCT APPROVAL (COVER SHEET WITH FL#)
 SHALL BE SUBMITTED WITH THE PRODUCT
 NOA'S
  
 7) ALL NOA'S SHALL BE MARKED (HILIGHTED)
 TO CLEARLY SHOW THE INSTALLATION METHOD
 AND ANY INFORMATION NEEDED PER THE
 GENERAL LIMITATIONS OF THE PRODUCT, SUCH
 AS ENHANCED FASTENING FOR WIND LOADS
  
 8) ATTACHED GARAGES REQUIRE A RADON FEE
 TO BE COLLECTED PER CHAPTER 10D-91, OF
 THE FLORIDA ADMINISTRATION CODE
 10D-91.1313 AND 10D-91.1314
  
  
 BLDG PLAN REVIEW