| 2006-01-26 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05110890 |
| | ADD: 5400 S DIXIE |
| | CONT:PLAN REVIEW ONLY |
| | TEL: (954)816-3351 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) TRUSS TIE DOWNS |
| | B) PRE FABRICATED CANOPIES |
| | C) METAL ROOF NON-STRUCTURAL |
| | D) BAHAMA SHUTTERS |
| | THE AEICOR METAL ROOF SUBMITED HAS A |
| | MAXIMUM DESIGN PRESSURE OF -37.5 WHERE |
| | AS IN ZONE 3 A -68.1.SEE SYSTEMS |
| | LIMITATION # 1. ALL RATIONAL ANALYSIS |
| | COMPUTATION SHALL BE PREPARED, SIGNED, |
| | SEALED BY A FL REGISTERED PROFESSIONAL |
| | ENGINEER , REGISTERED ARCHITECT OR |
| | REGISTERED ROOF CONSULTANT.SEE |
| | STRUCTURAL PLAN ZONE 3 -121.9 TAKEN AS A |
| | "C" EXPOSURE. |
| | |
| | 2) THE PRE FABRICATED CANOPY SHOULD |
| | HIGHLIGHT WHAT SYSTEM TO BE USED. PLANS |
| | INDICATE FOOTERS BUT THE COLUMNS BY |
| | OTHERS, DOES THIS MEAN THAT THE COLUMNS |
| | WILL BE BOLTED TO THE TOP OF THE FOOTER/ |
| | |
| | 3) NORTH ENTRY, HANDICAPPED ACCESS AISLE |
| | HAS A BOLLARD DIRECTLY IN THE CENTER OF |
| | THE WALKWAY FOR EACH ACCESS AISLE. |
| | |
| | 4) THE BAHAMA STYLE SHUTTERS DO NOT NEED |
| | |
| | STATE APPROVAL BUT THAT THE INSTALLATION |
| | WILL BE FORE A FIXED OPEN POSITION |
| | DURING A HIGH WIND EVENT. |
| | |
| | 5)THE SITE PLAN A1.01 DOES NOT INDICATE |
| | THE LOCATION OF THE CANOPY ON THE SOUTH |
| | SIDE OF THE BUILDING. A3.01 DETAIL 5 THE |
| | CANOPY APPEARS TO HAVE A DRIVE THROUGH |
| | THE WAY THE CURBS ARE DETAILED, WHEREAS |
| | THE SITE PLAN SHOWS PARKING SPACES, |
| | PLEASE CLARIFY. |
| | |
| | THIS REVIEW WILL CONTINUE 1-30-06 |