Plan Review Notes
Plan Review Notes For Permit 05110890
Permit Number 05110890
Review Stop B
Sequence Number 1
Notes
Date Text
2006-01-26 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05110890
 ADD: 5400 S DIXIE
 CONT:PLAN REVIEW ONLY
 TEL: (954)816-3351
 FL BLD CODE= 2001 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 FL BLD CODE 1606.1.5: COMPONENTS &
 CLADDING, PROVIDE 2 COPIES(3 IF THRESH-
 OLD OR RESIDENT INSPECTOR) OF PRODUCT
 TESTING REPORTS,MISSING REPORTS ARE AS
 FOLLOWS:
 A) TRUSS TIE DOWNS
 B) PRE FABRICATED CANOPIES
 C) METAL ROOF NON-STRUCTURAL
 D) BAHAMA SHUTTERS
 THE AEICOR METAL ROOF SUBMITED HAS A
 MAXIMUM DESIGN PRESSURE OF -37.5 WHERE
 AS IN ZONE 3 A -68.1.SEE SYSTEMS
 LIMITATION # 1. ALL RATIONAL ANALYSIS
 COMPUTATION SHALL BE PREPARED, SIGNED,
 SEALED BY A FL REGISTERED PROFESSIONAL
 ENGINEER , REGISTERED ARCHITECT OR
 REGISTERED ROOF CONSULTANT.SEE
 STRUCTURAL PLAN ZONE 3 -121.9 TAKEN AS A
 "C" EXPOSURE.
  
 2) THE PRE FABRICATED CANOPY SHOULD
 HIGHLIGHT WHAT SYSTEM TO BE USED. PLANS
 INDICATE FOOTERS BUT THE COLUMNS BY
 OTHERS, DOES THIS MEAN THAT THE COLUMNS
 WILL BE BOLTED TO THE TOP OF THE FOOTER/
  
 3) NORTH ENTRY, HANDICAPPED ACCESS AISLE
 HAS A BOLLARD DIRECTLY IN THE CENTER OF
 THE WALKWAY FOR EACH ACCESS AISLE.
  
 4) THE BAHAMA STYLE SHUTTERS DO NOT NEED
  
 STATE APPROVAL BUT THAT THE INSTALLATION
 WILL BE FORE A FIXED OPEN POSITION
 DURING A HIGH WIND EVENT.
  
 5)THE SITE PLAN A1.01 DOES NOT INDICATE
 THE LOCATION OF THE CANOPY ON THE SOUTH
 SIDE OF THE BUILDING. A3.01 DETAIL 5 THE
 CANOPY APPEARS TO HAVE A DRIVE THROUGH
 THE WAY THE CURBS ARE DETAILED, WHEREAS
 THE SITE PLAN SHOWS PARKING SPACES,
 PLEASE CLARIFY.
  
 THIS REVIEW WILL CONTINUE 1-30-06