 DENIED
  
 1) NEW NOA UNDER LIMITATION (1) EXCLUDES
 THE USE OF RATIONAL ANALYSIS TO
 DETERMINE ENHANCED FASTENING.
  
 NOTE: USING THE SIMPLIFIED METHOD IN THE
 2004 FBC TABLE 1609.6B 140 MPH EXPOSURE
 B. A 12/12 SLOPE WITH 10 SQ FT EFFECTIVE
 AREA HAS A WIND LOAD OF -41.2 WHICH THE
 NOA EXCEEDS BUT THE MEAN ROOF HEIGHT IS
 38 FT AND THE LOAD MUST BE ADJUSTED BY A
 FACTOR OF 1.05 = -43.26 WHICH NOW
 EXCEEDS THE NOA.
 CAN YOUR ENGINEER MEET THIS CRITERIA, IF
 NOT THIS PRODUCT WILL NOT BE ACCEPTED
  
  