| Plan Review Notes For Permit 05110838 |
| Permit Number |
05110838 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2005-12-21 00:00:00 | | | | | | | DENIED | | | | | | 1) NEW NOA UNDER LIMITATION (1) EXCLUDES | | | THE USE OF RATIONAL ANALYSIS TO | | | DETERMINE ENHANCED FASTENING. | | | | | | NOTE: USING THE SIMPLIFIED METHOD IN THE | | | 2004 FBC TABLE 1609.6B 140 MPH EXPOSURE | | | B. A 12/12 SLOPE WITH 10 SQ FT EFFECTIVE | | | AREA HAS A WIND LOAD OF -41.2 WHICH THE | | | NOA EXCEEDS BUT THE MEAN ROOF HEIGHT IS | | | 38 FT AND THE LOAD MUST BE ADJUSTED BY A | | | FACTOR OF 1.05 = -43.26 WHICH NOW | | | EXCEEDS THE NOA. | | | CAN YOUR ENGINEER MEET THIS CRITERIA, IF | | | NOT THIS PRODUCT WILL NOT BE ACCEPTED | | | | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|