Plan Review Notes
Plan Review Notes For Permit 05110482
Permit Number 05110482
Review Stop B
Sequence Number 2
Notes
Date Text
2006-07-06 00:00:00DENIED
  
 ALL NEW COMMENTS:
  
 ** PROJECT DESCRIPTION ON APPLICATION
 DOES NOT DESCRIBE PROJECT IN DETAIL.
 THIS PROJECT IS A "CHANGE OF OCCUPANCY"
 TO AN EXISTING BUILDING. SEE THE
 FOLLOWING COMMENTS FOR REQUIRED
 INFORMATION NEEDED WITH A CHANGE OF
 OCCUPANCY.
  
 1. FBC 106.3.5 MINIMUM PLAN REVIEW
 CRITERIA FOR BUILDINGS.
 THE EXAMINATION OF THE DOCUMENTS BY THE
 BUILDING OFFICIAL SHALL INCLUDE THE
 FOLLOWING MINIMUM CRITERIA AND
 DOCUMENTS: A FLOOR PLAN; SITE PLAN;
 FOUNDATION PLAN; FLOOR/ROOF FRAMING PLAN
 OR TRUSS LAYOUT; AND ALL EXTERIOR
 ELEVATIONS.
  
 COMMERCIAL BUILDINGS:
  
 BUILDING
 1.SITE REQUIREMENTS:
  
 PARKING
 FIRE ACCESS
 VEHICLE LOADING
 DRIVING/TURNING RADIUS
 FIRE HYDRANT/WATER SUPPLY/POST INDICATOR
 VALVE (PIV)
 SET BACK/SEPARATION (ASSUMED PROPERTY
 LINES)
 LOCATION OF SPECIFIC TANKS, WATER LINES
 AND SEWER LINES
 2.OCCUPANCY GROUP AND SPECIAL
 OCCUPANCY REQUIREMENTS SHALL BE
 DETERMINED.
 3.MINIMUM TYPE OF CONSTRUCTION
 SHALL BE DETERMINED (SEE TABLE 503 ).
 4.FIRE-RESISTANT CONSTRUCTION
 REQUIREMENTS SHALL INCLUDE THE FOLLOWING
 COMPONENTS:
  
 FIRE-RESISTANT SEPARATIONS
 FIRE-RESISTANT PROTECTION FOR TYPE OF
 CONSTRUCTION
 PROTECTION OF OPENINGS AND PENETRATIONS
 OF RATED WALLS
 FIRE BLOCKING AND DRAFTSTOPPING AND
 CALCULATED FIRE RESISTANCE
 5.FIRE SUPPRESSION SYSTEMS SHALL
 INCLUDE:
  
 EARLY WARNING SMOKE EVACUATION SYSTEMS
 SCHEMATIC FIRE SPRINKLERS
 STANDPIPES
 PREENGINEERED SYSTEMS
 RISER DIAGRAM
 SAME AS ABOVE.
 6.LIFE SAFETY SYSTEMS SHALL BE
 DETERMINED AND SHALL INCLUDE THE
 FOLLOWING REQUIREMENTS:
  
 OCCUPANT LOAD AND EGRESS CAPACITIES
 EARLY WARNING
 SMOKE CONTROL
 STAIR PRESSURIZATION
 SYSTEMS SCHEMATIC
 7.OCCUPANCY LOAD/EGRESS
 REQUIREMENTS SHALL INCLUDE:
  
 OCCUPANCY LOAD
 GROSS
 NET
 MEANS OF EGRESS
 EXIT ACCESS
 EXIT
 EXIT DISCHARGE
 STAIRS CONSTRUCTION/GEOMETRY AND
 PROTECTION
 DOORS
 EMERGENCY LIGHTING AND EXIT SIGNS
 SPECIFIC OCCUPANCY REQUIREMENTS
 CONSTRUCTION REQUIREMENTS
 HORIZONTAL EXITS/EXIT PASSAGEWAYS
 8.STRUCTURAL REQUIREMENTS SHALL
 INCLUDE:
  
 SOIL CONDITIONS/ANALYSIS
 TERMITE PROTECTION
 DESIGN LOADS
 WIND REQUIREMENTS
 BUILDING ENVELOPE
 STRUCTURAL CALCULATIONS (IF REQUIRED)
 FOUNDATION
 WALL SYSTEMS
 FLOOR SYSTEMS
 ROOF SYSTEMS
 THRESHOLD INSPECTION PLAN
 STAIR SYSTEMS
 9.MATERIALS SHALL BE REVIEWED AND
 SHALL AT A MINIMUM INCLUDE THE
 FOLLOWING:
  
 WOOD
 STEEL
 ALUMINUM
 CONCRETE
 PLASTIC
 GLASS
 MASONRY
 GYPSUM BOARD AND PLASTER
 INSULATING (MECHANICAL)
 ROOFING
 INSULATION
 10.ACCESSIBILITY REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING:
  
 SITE REQUIREMENTS
 ACCESSIBLE ROUTE
 VERTICAL ACCESSIBILITY
 TOILET AND BATHING FACILITIES
 DRINKING FOUNTAINS
 EQUIPMENT
 SPECIAL OCCUPANCY REQUIREMENTS
 FAIR HOUSING REQUIREMENTS
 11.INTERIOR REQUIREMENTS SHALL
 INCLUDE THE FOLLOWING:
  
 INTERIOR FINISHES (FLAME SPREAD/SMOKE
 DEVELOPMENT)
 LIGHT AND VENTILATION
 SANITATION
  
 3.PRODUCT APPROVALS REQUIRED FOR FLAT
 ROOF.ONLY UNDERLAYMENT SUBMITTED.
 SUBMIT AND ATTACH STATE PRODUCT
 APPROVAL.
  
 4.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 6.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 7.SHOW COMPLIANCE WITH 2004 EXISTING
 BUILDING CODE CHAPTER 8 CHANGE OF
 OCCUPANCY.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE . A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672
  