Plan Review Notes
Plan Review Notes For Permit 05110446
Permit Number 05110446
Review Stop P
Sequence Number 1
Notes
Date Text
2005-12-15 00:00:00DENIED
 REFERENCE:FBC-2004 424.2 SWIMMING POOLS
  
 1) COMPLY WITH FBC-2004 SEC 424.2
 PRIVATE SWIMMING POOLS.(ADD TO NOTES)
 2) FBC-2004 424.2.7.2 PUMPS AND
 EQUIPMENT SHALL BE MOUNTED ON A
 SUBSTANTIAL BASE IN A MANNER THAT WILL
 ELIMINATE STRAIN ON PIPING.SLAB SHALL
 BE A NOMINAL 4" THICK. (DETAIL)(ADD TO
 NOTES)
 3)FBC-2004 424.2.9 WATER SUPPLY,LOCAL
 ORD. #2853-95, BACKFLOW REQUIRED ON
 WATER SERVICE.(ADD TO NOTES)
 4) FBC-2004 424.2.12.1 PRESSURE TESTS.
 PER MANUFACTURE RECOMMENDATIONS, NO AIR
 TEST SHALL BE APPROVED FOR PVC PIPE AND
 FITTINGS. (ADD TO NOTES)
 5) FBC-2004 424.2.13.2 JOINTS AND
 CONNECTIONS,FBC PLMG. SEC. 605.21,
 PURPLE PRIMER REQUIRED ON PVC PIPING.
 (ADD TO NOTES)
  