| Date |
Text |
| 2006-01-25 00:00:00 | DENIED |
| | |
| | |
| | 3.PLEASE SIGN OWNER/AGENT ON ENERGY |
| | CALCS. |
| | |
| | 5.ALL PRODUCT APPROVALS SUBMITTED |
| | SHALL HAVE THE FOLLOWING STATE PRODUCT |
| | APPROVAL ATTACHED. |
| | PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | |
| | 8.R613.6.2 MASONRY, CONCRETE OR OTHER |
| | STRUCTURAL SUBSTRATE. |
| | ANCHORS SHALL BE SECURELY FASTENED |
| | DIRECTLY INTO THE MASONRY, CONCRETE OR |
| | OTHER STRUCTURAL SUBSTRATE MATERIAL. |
| | UNLESS OTHERWISE TESTED, BUCKS SHALL |
| | EXTEND BEYOND THE INTERIOR FACE OF THE |
| | WINDOW OR DOOR FRAME SUCH THAT FULL |
| | SUPPORT OF THE FRAME IS PROVIDED. |
| | REVISE BUCK DETAIL TO SHOW FULL SUPPORT |
| | OF THE FRAME. |
| | |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | ART LANGE |
| | BUILDING PLANS EXAMINER |
| | 805-6672 |