Plan Review Notes
Plan Review Notes For Permit 05110205
Permit Number 05110205
Review Stop P
Sequence Number 1
Notes
Date Text
2005-12-13 00:00:00DENIED;
 1) FBC-2004424.2.6.6.5 WHERE PROVIDED,
 THE VACUUM OR PRESSURE CLEANER FITTING
 SHALL BE LOCATED AT LEAST 6" AND NOT
 GREATER THAN 12" BELOW THE MINIMUM OPER-
 ATING WATER LEVEL OR AS AN ATTACHMENT TO
 THE SKIMMER.
 15) FBC-2004 424.2.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. MANUFACTURE
 SHEETS REQUIRED. (SUBMITTAL) PLAN CALLS
 FOR A GAS HEATER, SUBMITAL SHEET IS FOR
 A HEAT PUMP. PLEASE REVISE.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695