| Date |
Text |
| 2006-02-28 00:00:00 | |
| | 1)ALL PLANS SUBMITTED AFTER OCTOBER, 1, |
| | 2004 SHALL BE DESIGNED TO THE 2004 |
| | FLORIDA BUILDING CODE. |
| | |
| | 2)THOSE PRODUCT APPROVALS WHICH ARE |
| | REGULATED BY DCA RULE 9B-72 SHALL BE |
| | REVIEWED AND APPROVED IN WRITING BY THE |
| | DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. THE CITY |
| | WPB AMMENDMENT TO FBC 106.3.3. EACH |
| | PRODUCT APPROVAL NEEDS ITS OWN STATE |
| | COVER SHEET WITH THE FL#. |
| | |
| | 3) THE SCALE ON PAGE 1.1 SHOWS 1"=1' |
| | HOWEVER WHEN SCAILING THE DRAWINGS, THIS |
| | SCALE WON'T WORK. PLEASE CLARIFY. |
| | |
| | 4) ON PAGE 3.1 INDICATE THE SLOPE OF THE |
| | NEW RAMP.SEE F.B.C. 11-4.8. ALSO, IN |
| | REFERENCE TO THE DETAILS OF SHEET 8.3, |
| | WHERE IS SHEET 8.3? |
| | |
| | 5) THE ADDRESS ON THE PAGES NEED TO |
| | MATCH NEED TO MATCH. SOME INDICATE 2025 |
| | N.DIXIE HIGHWAY AS THE ADDRESS AND |
| | OTHERS HAVE 2025 S.DIXIE HIGHWAY. MAKE |
| | SURE ALL SHEETS SHOW THE SAME ADDRESS. |
| | |
| | 6) (2004 FBC) 106.1.1 INFORMATION ON |
| | CONSTRUCTION DOCUMENTS. CONSTRUCTION |
| | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE & |
| | EXTENT OF THE WORK PROPOSED & SHOW IN |
| | DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND REVELENT |
| | LAWS, ORDINANCES, AND RULES AND |
| | REGULATIONS AS DETERMINED BY THE |
| | BUILDING OFFICIAL. |
| | |
| | 7) 109.3.10* IMPACT OF CONSTRUCTION. ALL |
| | CONSTRUCTION ACTIVITY REGULATED BY THIS |
| | CODE SHALL BE PERMORMED IN A MANNER SO |
| | AS NOT TO ADVERSLY IMPACT THE CONDITION |
| | OF ADJACENT PROPERTY, UNLESS SUCH |
| | ACTIVITY IS PERMITTED TO AFFECT SAID |
| | PROPERTY PURSUANT TO A CONSENT BY THE |
| | APPLICABLE PROPERTY OWNER, UNDER TERMS |
| | &CONDITIONS AGREEABLE TO THE APPLICABLE |
| | PROPERTY OWNER.THIS INCLUDES BUT IS NOT |
| | LIMITED TO THE CONTROL OF DUST, NOISE, |
| | WATER OR DRAINAGE RUN-OFF, DEBRIS, AND |
| | THE STORAGE OF CONSTRUCTION MATERIALS. |
| | NEW CONSTRUCTION ACTIVITY SHALL NOT |
| | ADVERSELY IMPACT HISTORIC SURFACE WATER |
| | DRAINAGE FLOWS SERVING ADJACENT |
| | PROPERTIES, & MAY REQUIRE SPECIAL |
| | DRAINAGE DESIGNCOMPLYING WITH |
| | ENGINEERING STANDARDS TO PRESERVE THE |
| | POSITIVE PATTERNS OF THE AFFECTED |
| | SITES.ACCORDINGLY, DEVELOPERS, |
| | CONTRACTORS, AND OWNERS OF ALL NEW |
| | RESIDENTIAL DEVELOPMENET, INCLUDING |
| | ADDITIONS, POOLS, PATIOS, DRIVEWAYS, |
| | DECKS, OR SIMILAR ITEMS, ON EXISTING |
| | PROPERTIES RESULTING IN A DECREASE IN |
| | EXCESS OF 800SQ FT OF PERMEABLE LAND |
| | AREA ON ANY PARCELL SHALL AS A PERMIT |
| | CONDITION, PROVIDE A PROFESSIONALY |
| | PREPARED DRAINAGE PLAN CLEARLY |
| | INDICATING COMPLIANCE WITH THIS |
| | PARAGRAPH. UPON COMPLETION OF THE |
| | IMPROVEMENT, A CERTIFICATE FROM A |
| | LICENSED ENGINEER SHALL BE SUBMITTED TO |
| | THE INSPECTOR IN ORDER TO RECEIVE |
| | APPROVAL OF THE FINAL INSPECTION. |
| | |
| | 8) BEFORE A PERMIT TO CONSTRUCT, MAY BE |
| | ISSUED, IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | 9)11-4.6.2 LOCATION. |
| | ACCESSIBLE PARKING SPACES SERVING A |
| | PARTICULAR BUILDING SHALL BE LOCATED ON |
| | THE SHORTEST SAFELY ACCESSIBLE ROUTE OF |
| | TRAVEL FROM ADJACENT PARKING TO AN |
| | ACCESSIBLE ENTRANCE. IN PARKING |
| | FACILITIES THAT DO NOT SERVE A |
| | PARTICULAR BUILDING, ACCESSIBLE PARKING |
| | SHALL BE LOCATED ON THE SHORTEST |
| | ACCESSIBLE ROUTE OF TRAVEL TO AN |
| | ACCESSIBLE PEDESTRIAN ENTRANCE OF THE |
| | PARKING FACILITY. IN BUILDINGS WITH |
| | MULTIPLE ACCESSIBLE ENTRANCES WITH |
| | ADJACENT PARKING , ACCESSIBLE PARKING |
| | SPACES SHALL BE DISPERSED AND LOCATED |
| | CLOSEST TO THE ACCESSIBLE ENTRANCES. |
| | EACH PARKING SPACE MUST BE NO LESS THAN |
| | 12 FEET (3658 MM) WIDE. |
| | (1)ALL SPACES MUST BE LOCATED ON AN |
| | ACCESSIBLE ROUTE NO LESS THAN 44 INCHES |
| | (1118 MM)WIDE SO THAT USERS WILL NOT BE |
| | COMPELLED TO WALK OR WHEEL BEHIND PARKED |
| | VEHICLES. SEE ADDITIONAL INFORMATION IN |
| | PACKAGE. |
| | |
| | 10) SHEET 4.1. STATE THE MEAN ROOF |
| | HEIGHT ON THE DRAWINGS. ALSO WHAT IS THE |
| | LIVE AND DEAD LOAD FOR THE MEZZANINE |
| | AREA? WHAT WILL THE MEZZANINE BE USE FOR |
| | STORAGE OR WILL THERE BE WORK TAKING |
| | PLACE ON THE MEZZANINE. |
| | SEE FBC 11-4.1.3 (1-5) FOR |
| | ACCESSIBILITY. |
| | |
| | 11) EXPLAIN WHAT TYPE OF WORK IS CARRIED |
| | OUT IN THE WORKSHOP AREA. WHAT WILL BE |
| | DISPLAYED IN THE SHOW ROOMS? |
| | |
| | 12) ADDITIONAL INFORMATION IS REQUIRED |
| | FOR THE BRACING AROUND THE HOLES FOR THE |
| | A/C UNITS. A DETAIL DRAWING IS REQUIRED |
| | SHOWING ALL BRACING. |
| | |
| | 13) SHEET 4.1 REFERENCE CERTAIN DETAIL |
| | AND PAGES WHICH CANNOT BE LOCATED ON THE |
| | DRAWINGS. MODIFY DRAWINGS ACCORDINGLY TO |
| | SHOW CORRECT DETAILS. |
| | |
| | 14) PROVIDE AN FRONT ELEVATION OF THE |
| | MEZZANINE SHOWING THE FIRST FLOOR HEIGHT |
| | AND THEMEZZANINE. ALSO SHOW THE |
| | GUARDRAIL. A DETAIL DRAWING OF THE |
| | GUARDRAIL IS ALSO REQUIRED. WHAT IS THE |
| | HEIGHT OF THE WALL? IS IT 42" OR 4'? |
| | WILL THERE BE AHY OPENING IN THIS WALL? |
| | IF SO SHOW ON ELEVATION DRAWINGS. |
| | |
| | 15) 713.13 F.S.A NOTICE OF |
| | COMMENCEMENT SHALL BE RECORDED AT PALM |
| | BEACH COUNTY COURTHOUSE AND A COPY |
| | SUBMITTED TO THIS OFFICE BEFORE A PERMIT |
| | CAN BE ISSUED. BLANK FORMS ARE AVAILABLE |
| | FROM THIS OFFICE. |
| | NOTE: THE NOTICE OF COMMENCEMENT MUST BE |
| | RE-RECORDED IF THE DESCRIBED IMPROVEMENT |
| | OR CONSTRUCTION IS NOT COMMENCED WITHIN |
| | 90 DAYS OF RECORDING. |
| | |
| | MYRON JACOBS |
| | BUILDING PLAN REVIEWER |
| | TEL:(561)805-6726 |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |