| 2006-05-02 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2004 |
| | FBC* CITY OF WEST PALM BEACH AMENDMENTS |
| | TO THE FBC2004 |
| | |
| | FROM PREVIOUS LISTS: |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | THE NOC PROVIDED IS EXPIRED, OVER 90 |
| | DAYS WITHOUT COMMENCING WORK |
| | FS713.13(2). |
| | |
| | 2.)PROVIDE BUILDING MEAN ROOF HEIGHT. |
| | DESIGN PRESSURES FOR BUILDINGS OVER |
| | 60FEET ARE REQUIRED TO BE DESIGNED USING |
| | ASCE7, FBC1609.1.1.DOCUMENTS PREPARED |
| | BY AN ENGINEER AND SUBMITTED FOR PUBLIC |
| | RECORD ARE TO BE SIGNED SEALED ORIGINALS |
| | FAC61G15-23.002. |
| | |
| | (SECOND REVIEW) THE SCHEDULE GIVES |
| | DESIGN PRESSURES OF -13.5 AND -14.1, BUT |
| | -45 IS CIRCLED ON SHEET 9 OF THE PRODUCT |
| | APPROVAL.DESIGN PRESSURES ARE TO BE |
| | DETERMINED BY FBC TABLE 1609.6B AND |
| | 1609.6D. |
| | |
| | (THIRD REVIEW) A NEW SCHEDULE GIVES THE |
| | WORST CASE PRESSURE AS -54.5 BUT PAGE 9 |
| | HAS -45 CIRCLED.NO ANCHORING IS |
| | SPECIFIED ON EITHER THE INSTALLATION |
| | SCHEDULE OR ON THE TABLES ON THE PRODUCT |
| | APPROVALS. |
| | |
| | 3.)ADDRESSED. |
| | |
| | 4.)COMPLETE THE ATTACHED INSTALLATION |
| | SCHEDULE, OR PROVIDE REQUIRED |
| | INFORMATION IN A SIMILAR FORMAT.SEE |
| | ATTACHED POLICY. |
| | |
| | (SECOND REVIEW) THE FORM WAS NOT FILLED |
| | OUT CORRECTLY (ALL COLUMNS BLANKEXCEPT |
| | FOR DPS WHICH ARE INCORRECT).NO ANCHOR |
| | SPACING INDICATED ON PRODUCT APPROVAL. |
| | NOT ENOUGH INFORMATION PROVIDED TO |
| | DETERMINE CODE COMPLIANCE. |
| | |
| | (THIRD REVIEW) SAME PAPERWORK SUBMITTED. |
| | NO ANCHORING SPECIFIED. |
| | |
| | NEW COMMENT: |
| | |
| | 5.)ONLY ONE PRODUCT APPROVAL WAS |
| | SUBMITTED. SUBMIT TWO COPIES OF ALL |
| | DOCUMENTS FOR PERMITTING. |