Date Text
2006-01-06 00:00:00BUILDING PLAN REVIEW
 PERMIT: 05100946
 ADD: 430 HIBISCUS ST
 CONT: THE TOWER GROUP CGCA38309
 TEL: (954)474-3111
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1) PROVIDE NOC RECORDED WITH THE CLERK
 OF COURT BEFORE A PERMIT CAN BE ISSUED.
 NOTE: 713.13.(2) IF WORK HASN'T STARTED
 WITHIN 90 DAYS OF THE NOC BEING RECORDED
 SUCH NOTICE WILL BE VOID AND NO FURTHER
 IN EFFECT CAUSING IT TO BE RE-RECORDED.
  
 2) THERE SEEMS TO BE A DISCREPANCY
 BETWEEN THE PERMIT APPLICATION AND PLANS
 AS TO THE ADDRESS AS WELL AS THE
 PROPERTY CONTROL NUMBER.
 2A) PERMIT APPLICATION INDICATES 430
 HIBISCUS WHERE AS THE PLANS INDICATE 480
 HIBISCUS.
 2B) THE PCN SUPPLIED ON THE PERMIT
 APPLICATION INDICATES A SINGLE LOT. A0.2
 APPEARS TO TAKE MOST OF THE BLOCK AND
 CROSSING THE ALLEYWAY. PROVIDE A REPLAT
 INDICATING A SINGLE LOT AND NEW PCN.
 2C) BEFORE THE FOUNDATION PLAN IS
 RESUBMITTED CORRALATE ALL PLANS INTO
 THREE COMPLETE SETS AND STAPLED.
 106.1.2 ADDITIONAL DATA. THE BUILDING
 OFFICIAL MAY REQUIRE DETAILS,
 COMPUTATIONS, STRESS DIAGRAMS, AND OTHER
 DATA NECESSARY TO DESCRIBE THE
 CONSTRUCTION OR INSTALLATION AND THE
 BASIS OF CALCULATION. ALL DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 REQUIRED BY THE BUILDING OFFICIAL TO BE
 PREPARED BY AN ARCHITECT OR ENGINEER
 SHALL BE AFFIXED WITH THIER OFFICIAL
 SEAL, SIGNATURE AND DATE AS STATE LAW
 REQUIRES.
  
 3A) 104.4.5. SPECIAL FOUNDATION PERMIT
 WHEN APPLICATION FOR A PERMIT TO ERECT
 OR ENLARGE A BUILDING HAS BEEN FILED, &
 PENDING ISSURANCE OF SUCH PERMIT, THE
 BUILDING OFFICIAL MAY, AT HIS/ HER
 DISCRETION, ISSUE A SPECIAL PERMIT FOR
 THE FOUNDATION ONLY, UPON WRITTEN RE-
 QUEST OF THE OWNER AND CONTRACTOR. THE
 HOLDER OF SUCH A SPECIAL PERMIT IS PRO-
 CEEDING AT HIS OR HER OWN RISK AND WITH-
 OUT ASSURANCE THAT A PERMIT FOR THE
 REMAINDER OF THE WORK WILL BE GRANTED
 AND THAT CORRECTIONS WILL NOT BE RE-
 QUIRED IN ORDER TO MEET THE PROVISIONS
 OF THE TECHNICAL CODE.
 3B) WHEN A FOUNDATION PERMIT IS APPLIED
 FOR IT IS UNDERSTOOD THAT INCLUDES FLOOR
 SLABS REQUIRING MEP PLANS. IF LOOKING
 FOR A PERMIT TO START WORK WITHOUT THE
 REQUIRED MEP SHEETS INDICATE WHAT WORK
 WILL BE COMPLETED UNDER THIS PERMIT.
 THE PERMIT APPLICATION BOX DESCRIPTION
 OF PROJECT SHOULD INCLUDE WHAT TYPE OF
 WORK IS TO BE COMPLETED UNDER THIS
 FOUNDATION PERMIT.
  
 4)FL S. S. 553.71(7) " THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS
 GREATER THAN (3) STORIES OR 50 FT IN
 HEIGHT, OR WHICH HAS AN ASSEMBLY OCCUPAN
 CY CLASSIFICATION AS DEINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS
 5,000 SQ FT IN AREA AND AN OCCUPANT
 CONTENT OF GREATER THAN 500 PERSONS.
 105.13.1 THE ENFORCING AGENCY SHALL
 REQUIRE A SPECIAL INSPECTOR TO PERFORM
 SRUCTURAL INSPECTIONS ON A THRESHOLD
 BUILDING PURSUANT TO A STRUCTURAL INSPEC
 TION PLAN PREPARED BY THE ENGINEER OF
 RECORD. THE STRUCTURAL INSPECTION PLAN
 MUST BE SUBMITTED TO THE ENFORCING AGEN-
 CY PRIOR TO THE ISSUANCE OF A BUILDING
 PERMIT FOR THE CONSTRUCTION OF A THRESH-
 OLD BUILDING. THE PURPOSE OF THE SRUCTUR
 AL INSPECTION PLAN IS TO PROVIDE SPECIF-
 IC INSPECTION PROCEDURES AND SCHEDULES
 SO THAT THE BUILDING CAN BE ADEQUATELY
 INSPECTED FOR COMPLIANCE WITH THE
 PERMITTED DOCUMENTS.
  
 5) WPB AMENDMENT 105.13.6. W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT
 REQUEST FOR THRESHOLD BUILDINGS A
 SPECIAL INSPECTOR AS REQUIRED BY S.
 553.79(5) FLORIDA STATUTES TO THE MIN-
 IMUM INSPECTIONS REQUIRED BY THIS CODE.
 CONTACT HAROLD PISKURA MANAGER OF THE
 SPECIAL INSPECTOR PROGRAM AT (561)
 805-6711 FOR FURTHER INFORMATION BEFORE
 THE PERMIT MAY BE ISSUED.
  
 6) W.P.B. AMENDMENT 105.13.4.4 ALL PLANS
 FOR THE BUILDING WHICH ARE REQUIRED TO
 BE SIGNED AND SEALED BY THE ARCHITECT OR
 ENGINEER OF RECORD CON- TAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S PR
 ENGINEER'S KNOWLEDGE, THE PLANS AND
 SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS
 DETERMINED BY THE LOCAL AUTHORITY IN
 ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTE.
  
 7)106.1.2 ADDITIONAL DATA. THE
 BUILDING OFFICIAL MAY REQUIRE DETAILS,
 COMPUTATIONS, STRESS DIAGRAMS, AND OTHER
 DATA NECESSARY TO DESCRIBE THE
 CONSTRUCTION OR INSTALLATION AND THE
 BASIS OF CALCULATION. ALL DRAWINGS,
 SPECIFICATIONS AND ACCOMPANYING DATA
 REQUIRED BY THE BUILDING OFFICIAL TO BE
 PREPARED BY AN ARCHITECT OR ENGINEER
 SHALL BE AFFIXED WITH THIER OFFICIAL
 SEAL, SIGNATURE AND DATE AS STATE LAW
 REQUIRES.
 THE STRUCTURAL PLANS START WITH
 SHEET S-1.0 BUT THE STRUCTURAL NOTES
 START WITH NUMBER (4).
 THERE IS NO MENTION OF SOILS
 REQUIREMENTS, SOILS REPORTS,
 DENSEIFICATION, NOR AUGER PILE GRADE
 BEAMS, ETC?S1.1 SOIL NOTE SOIL TO BE
 DENSIFIED TO 8,000 BY VIBROFLOTATION,
 PROVIDE REPORT.
  
 8) SEE SHEET S-1.0 FOR IMPORTANCE
 FACTOR, ASCE 7-98 TABLE 1-1/ TABLE 6-1,
 BUILDINGS AND OTHER STRUCTURES WHERE
 MORE THAN 300 PEOPLE CONGREGATE IN ONE
 AREA WILL REQUIRE THE BUILDING CATEGORY
 BE A III AND THE IMPORTANCE FACTOR OF
 1.15. SEE POOL DECK AND WALKWAYS OF
 11,697 SQ FT / 30= 390 OCCUPANT LOAD.
  
 9) SHEET S1.1 FOOTING# 440140 NOT ON
 FOOTING SCHEDULE.STEEL?
  
 10) SHEET S1.1 FOOTING 200160 NOT ON
 FOOTING SCHEDULE. STEEL? THERE ARE
 NUMEROUS FOOTERS THAT ARE NOT ON THE
 SCHEDULE AND WILL REQUIRE STEEL PLEASE
 PROVIDE INFORMATION.
  
 11) BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026
  
  
  
  