| 2005-12-19 00:00:00 | ****CORRECTIONS**** |
| | |
| | SAMANTHA HILL, BUILDING PLANS EXAMINER |
| | 561-805-6724 [email protected] |
| | |
| | FBCFLORIDA BUILDING CODE 2004 |
| | FBC EBFLORIDA BUILDING CODE 2004 |
| | EXISTING BUILDING CODE |
| | FBC*CITY OF WEST PALM BEACH |
| | AMENDMENTS TO THE FBC2004 |
| | |
| | 1.)A NOTICE OF COMMENCEMENT MUST BE |
| | FILED WITH THE CLERK OF COURTS BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 2.)PROVIDE A SITE PLAN SHOWING THE |
| | PROPOSED IMPROVEMENT (TWO COPIES). |
| | |
| | 3.)SHEET S2 STRUCTURAL NOTES REFERS TO |
| | FBC2001; GOVERNING CODE IS FBC2004. |
| | |
| | 4.)SHEET S2, STRUCTURAL NOTES CODES |
| | AND STANDARDS HAS REFERENCES WHICH ARE |
| | OUTDATED AND IN CONFLICT WITH OTHER |
| | SPECIFICATIONS ON THIS SHEET.CHECK ALL |
| | REFERENCES, ALL SECTIONS. |
| | |
| | 5.)A NEW FIXED GLASS WINDOW IS SHOWN |
| | ON THE PLAN.PROVIDE PRODUCT APPROVAL. |
| | SEE ATTACHED POLICY IN REGARDS TO IMPACT |
| | PROTECTION.IF YOU PROPOSE THE USE OF |
| | REMOVABLE SHUTTERS, APPROVAL FROM THE |
| | BUILDING OFFICIAL IS REQUIRED. |
| | |
| | 6.)THE TRUSS PLACEMENT PLAN AND TRUSS |
| | DRAWINGS PREPARED BY JULIUS LEE'S |
| | CONSULTING ENGINEERING, PA ARE |
| | PHOTOCOPIES (ONE COPY).DOCUMENTS |
| | PREPARED BY AN ENGINEER AND SUBMITTED |
| | FOR PUBLIC RECORD ARE TO BE SIGNED, |
| | SEALED ORIGINALS. |
| | |
| | 7.)THE SPECIFICATION FOR HURRICANE |
| | STRAP H16 CONFLICTS WITH THE CATALOG. |
| | IF YOU WANT TO SPECIFY A DIFFERENT |
| | NUMBER OF FASTENERS, LOCAL PRODUCT |
| | APPROVAL REQUIRED, FAC9B72. |
| | WWW.FLORIDABUILDING.ORG |
| | |
| | 8.)FLORIDA STATE OR LOCAL PRODUCT |
| | APPROVAL REQUIRED FOR THE GAF SHINGLES, |
| | FAC9B72.WWW.FLORIDABUILDING.ORG |
| | |
| | 9.)PROVIDE WIND DESIGN DATA |
| | FBC1603.1.4. |
| | |
| | 10.)ROOF PERMIT REQUIRED (STRUCTURAL |
| | PERMIT ONLY WAS APPLIED FOR). |
| | |
| | |