| Plan Review Notes For Permit 05100175 |
| Permit Number |
05100175 |
|
| Review Stop |
M |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2005-10-12 00:00:00 | *** DENIED *** | | | 1) PLANS NEED JOB LOCATION AND | | | CONTRACTOR INFORMATION ON THEM. | | | 2) NEED ENERGY CAL'S. FORM 600 OR MANUAL | | | 'J' PER 2004 FBC CH.13 . | | | 4) NO RETURN AIR GRILL TO A.H.U. | | | SHOWING. | | | 5) RETURN AIR REQUIRED IN EACH BEDROOM | | | PER 2004 FBC/R M1602.4 . | | | IF YOU HAVE ANY QUESTIONS PLEASE CALL | | | TOM GORDON 805-6729 OR PATTY KRAUSS | | | 805-6719. |
|