| Plan Review Notes For Permit 05100073 |
| Permit Number |
05100073 |
|
| Review Stop |
E |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2006-04-28 00:00:00 | REDLINED ITEMS ON PLANS. | | | | | | | | | | | | 1) PLEASE SEE PLANS INDICATE A | | | DISCONNECT OUTSIDE WITH METER, HOWEVER | | | RISER SHOWS SLAB FEED TO MCB PANELS IN | | | GARAGE. ** WORK PER RISER NOTED ** | | | | | | 2) NOTE: PLEASE SEE NOTE MENTIONS FOR WP | | | LT FIXTURES TO BE CIRCUITED TO BATH | | | CIRCUIT? BATH CIRCUIT MAY NOT FEED | | | OUTDOOR LTS.* REDLINED** | | | | | | 3) MISSING LT FIXTURE IN EGRES HALL | | | UPSTAIRS. ** REDLINED ** | | | | | | | | | PLEASE REVISE THE ABOVE ALONG WIHT ANY | | | OTHER REVISIONS BEFORE ROUGH. IF NO | | | OTHER REVISIONS ARE MADE, THEN "REDLINED | | | PLANS" DO NOT NEED TO BE REVISED. |
|