| Date |
Text |
| 2007-09-28 14:25:24 | ****FAILED***** |
| | |
| | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). |
| | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR |
| | NOI. |
| | YOU CAN GET NOI INFO FROM |
| | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ |
| | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), |
| | EFFECTIVE MAY 1, 2003 |
| | 2. PLEASE SHOW ON CIVIL DRAWING THE EXACT MAILING |
| | ADDRESS, BUILDING NAME, OR NUMBER, YOU TALKING ABOUT 3 |
| | PERMITS, PLEASE IDENTIFY EACH BUILDING ON THE DRAWING. |
| | 3.PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE |
| | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION |
| | MUST BE ACCESSIBLE FOR PICKUP TRUCK. |
| | 4.PLEASE SHOW FINISH FLOOR ELEVATION ON DRAWING . |
| | PLEASE EXPLAIN IN DETERMINING FIRST FLOOR ELEVATION, |
| | PLEASE SHOW IN YOUR CALCULATION THAT YOU CONSIDERED |
| | CENTER LINE OF ROAD , FLOOD ZONE OF THIS SITE,& 5,10, |
| | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST |
| | FLOOR ELEVATION, PLEASE SHOW ALL THESE IN YOUR STORM |
| | WATER CALS.PLEASE ALSO SHOW ON DRAWINGS THE MAXIMUN |
| | AND MINIMUM PARKING LOT ELEVATIONS. |
| | |
| | 5. PLEASE SHOW ON DRAWINGTHE SITE AREA, YOU ARE |
| | DEVELOPING FOR THIS PROJECT . PLEASE ALSO SHOW TOTAL |
| | PERVIOUS,& IMPERVIOUS AREA FOR THIS PROJECT, |
| | LAKE,SIDEWALK, PARKING,BUILDING AREA ETC. MAKE SURE |
| | THESE AREAS SHOWN ON DRAWINGS MUST MATCH WITH AND USED |
| | IN STORM WATER QUALITY CALCULATIONS. |
| | 6. PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR SITE |
| | SO, WE CANSEE THE LAYOUT OF STORM WATER PIPES FROM |
| | ALL OTHER STORM WATER PIPES. PLEASE SHOW DETAIL OF THE |
| | CONTROL STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING |
| | ELEVATION, ETC ON DRAWINGS, CALCULATION FOR |
| | EXFILTRATION TRENCHES, PLEASE SHOW DRY DETENTION/WET |
| | DETENTION AREAS IN STORM WATER CALS.AFTER CONTROL |
| | STRUCTURE WHERE STORM WATER GOES?? |
| | 7. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND |
| | YOUR SITE FOR STORM WATER DRAIN. |
| | 8. PLEASE RESUBMIT A COPY OF SFWMD PERMIT,, & GEO TECH |
| | REPORT,STORM WATER CALS MUST BE APPROVED FROM 1000 |
| | 45TH STREET ENGINEERING SERVICES. |
| | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH |
| | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. |
| | 10. PLEASE KEEP SEPARATE CIVIL DRAWINGS SO I CAN REVIEW |
| | QUICK. |
| | |
| | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR |
| | PERMITTING PROCESS |
| | |
| | RASIK CHOKSHI805-6723 |