| Date |
Text |
| 2006-01-18 00:00:00 | DENIED |
| | REFERENCE: FBC-2001 PLUMBING |
| | FBC-2001 BUILDING |
| | FBC-2001 CHAPTER 1 |
| | FBC-2001 CHAPTER 11 |
| | FHA-98 DESIGN MANUAL |
| | FLORIDA ADMINISTRATIVE CODE |
| | FLORIDA STATUTES |
| | |
| | A. PLANS WERE SUBMITTED AS LOOSE SHEETS |
| | AND AS SUCH IS NOT ACCEPTABLE. PLEASE |
| | SUBMIT PLANS IN BOUND SETS. SECTION |
| | 104.2.1.3. |
| | B. PERMITS INDICATE 3 SEPARATE |
| | BUILDINGS, BUT PLANS INDICATE ONE |
| | BUILDING. PLEASE CLARIFY. SECTION |
| | 104.2.1. |
| | 1. ALL ARCHITECTURAL SHEETS, (EXCEPT FOR |
| | STRUCTURAL), ARE NOT SEALED AS REQUIRED |
| | IN SECTION 104.2.2 & FAC 61G1-16.003 |
| | 61G1-16.004(5) & FS 481.2055. |
| | 2. SHTS AP/A1.02 & AP/A1.03 SHOWN IN |
| | DRAWING INDEX ON SHT AP/A1.01 HAVE NOT |
| | BEEN SUBMITTED. SECTION 104.2.1. |
| | 3. SHTS AP/A5.24 & AP/A5.25 SUBMIT |
| | CALCULATIONS FOR PRIMARY AND SECONDARY |
| | ROOF DRAINS PER SECTIONS 1106 & 1107 AND |
| | ALL SUBSECTIONS. SHOW SF DRAINED FOR |
| | EACH AREA ALONG WITH 1/2 AREA OF ALL |
| | VERTICAL WALLS, INCLUDING PARAPETS, AND |
| | THE AREA OF ANY ROOFS THAT DRAIN ONTO |
| | THE ROOF AREAS FROM ABOVE. - SHOW THE |
| | LOCATION OF ALL SECONDARY ROOF DRAINS OR |
| | SCUPPERS. IF SCUPPERS ARE USED, SUBMIT A |
| | DETAIL SHOWING HEIGHT, WIDTH, AND |
| | DISTANCE TO FLOW LINE OFF THE ROOF. |
| | SECTION 1503.4.2 |
| | 4. SHTS AP/A5.61 & AP/A5.62 INDICATE |
| | SPECIFICATION "A" OR "B" FOR EACH UNIT |
| | OR BATHROOM AS REQUIRED IN FHA DESIGN |
| | MANUAL PAGES 7.34 & 7.35. - LAVS SHALL |
| | BE A MINIMUM OF 2' OFF THE WALL IN ORDER |
| | TO BE CENTERED ON THE 48" LENGTH OF THE |
| | CLEAR FLOOR SPACE. PLEASE INDICATE ON |
| | PLANS. FHA DESIGN MANUAL PAGES 7.47 AND |
| | 7.48. - WATER CLOSET OPENING SHALL BE A |
| | MINIMUM OF 33" WITH THE WATER CLOSET 18" |
| | OFF ONE FIXTURE AND 15" OFF THE OTHER |
| | FIXTURE TO THE CENTER OF THE W/C. FHA |
| | DESIGN MANUAL PAGES 7.43, 7.44, & 7.45. |
| | 5. SHT AP/A5.56 INDICATE MATERIAL FOR |
| | GRAB BAR BLOCKING. SECTION 104.2.1. |
| | 6. SHTS AP/A5.50 THRU AP/A5.55 LAV SHALL |
| | BE 34" TO TOP OF FIXTURE RIM, NOT 36" AS |
| | SHOWN. FHA DESIGN MANUAL PAGE 7.52. |
| | 7. SHTS AP/A6.01 THRU AP/A6.04 INDICATE |
| | THE BLDG. NUMBERS FOR EACH OF THE |
| | BUILDING ELEVATIONS. |
| | 8. SUBMIT A DETAIL FOR THE COMMON USE |
| | TOILET ROOMS SHOWING COMPLIANCE WITH |
| | SECTIONS 11-4.16, 11-4.19, & 11-4.22 AND |
| | ALL SUBSECTIONS. |
| | 9. SHTS AP/P14.02 UNITS B3 & B4 MAXIMUM |
| | 4 FU ON A 2" WET VENT IN MASTER BATH. |
| | TABLE 909.3 |
| | 10. SHT AP/P14.05 VENTS ARE REQUIRED FOR |
| | THE FLOOR DRAINS. SECTION 901.2.1. - |
| | CLEANOUTS ARE REQUIRED IN THE SANT. |
| | BUILDING DRAIN AT ALL CHANGES OF |
| | DIRECTION OVER 45 DEGREES. SECTION |
| | 708.3.3. |
| | 11. SHT AP/P14.26 OFFSETS IN THE SANT. |
| | SHALL BE SHOWN ON EITHER BLDG. DRAIN |
| | ISOMETRIC RISER DIAGRAM, OR SANT. RISER |
| | DIAGRAMS. SECTION 104.2.1. |
| | 12. SHT AP/P14.27 SANT. RISER S/9, |
| | PLEASE INDICATE FIXTURE TYPE FOR FIXTURE |
| | L-3. THIS IS NOT SHOWN ON PLUMBING |
| | FIXTURE SCHEDULE. SECTION 104.2.1. |
| | 13. SHT AP/P14.27 WATER HEATER PIPING |
| | DETAIL, THERMAL EXPANSION CONTROL IS |
| | REQUIRED PER SECTION 607.3.2. PLEASE |
| | INDICATE METHOD. - DIELECTRIC UNIONS ARE |
| | NOT APPROVED FOR WATER SUPPLY. |
| | DIELECTRIC COUPLING TO BE USED. |
| | 14. AN RPZV BACKFLOW IS REQUIRED ON THE |
| | WATER SERVICE TO THE BUILDING. SECTION |
| | 608.13.2. |
| | 15. SUBMIT A WATER LAYOUT FOR BUILDING |
| | AND WATER RISER DIAGRAMS. SHOW ALL PIPE |
| | SIZES, VALVES, WATER HAMMER ARRESTORS, |
| | (INSTALLED IN AN "EFFECTIVE RANGE" NOT |
| | IN THE CEILING). SECTIONS 104.3.1.1, |
| | 606.1, 606.2, 608.13.2 & PDI-WH 201. |
| | 16. SUBMIT A BUILDING SANITARY DRAIN |
| | ISOMETRIC RISER DIAGRAM SHOWING ALL PIPE |
| | SIZES, TRAPS, OFFSETS, RISER LOCATIONS |
| | WITH RISER NUMBERS, DFU'S AS THEY |
| | ACCUMULATE IN THE SYSTEM ETC. SECTION |
| | 104.3.1.1. |
| | 17. SUBMIT A BUILDING STORM DRAIN |
| | ISOMETRIC RISER DIAGRAM, SHOWING ALL |
| | PIPE SIZES, RISER LOCATIONS WITH RISER |
| | NUMBERS, AND SQUARE FEET AS IT |
| | ACCUMULATES IN THE SYSTEM. SECTION |
| | 104.3.1.1. |
| | 18. SUBMIT STORM RISER DIAGRAMS SHOWING |
| | ALL PIPE SIZES, OFFSETS, AND SQUARE |
| | FOOTAGE DRAINED FOR EACH RISER. |
| | |
| | REVIEW BY KEN STEVENS |
| | (561) 805-6721 |
| | FAX (561) 653-2692 |
| | E-MAIL [email protected] |
| | |
| | |