| 2005-10-31 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05091512 |
| | ADD: 1020 BEAR ISLAND DR |
| | CONT: O/B RICHARD LYNN |
| | TEL: (561)684-9381 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 1ST REVIEW |
| | ACTION: DENIED |
| | |
| | 1) FL BLD CODE 104.2.1.2 |
| | ADDITIONAL INFORMATION REQUIRED, PLEASE |
| | PROVIDE A FLOOR PLAN IDENTIFYING ALL THE |
| | ROOMS, WINDOW LOCATIONS, WINDOWS TO BE |
| | REPLACED, SIZE OF WINDOWS TO BE |
| | REPLACED. |
| | |
| | 2A) FL BLD CODE 1606.1.5: COMPONENTS & |
| | CLADDING, PROVIDE 2 COPIES(3 IF THRESH- |
| | OLD OR RESIDENT INSPECTOR) OF PRODUCT |
| | TESTING REPORTS,MISSING REPORTS ARE AS |
| | FOLLOWS: |
| | A) SINGLE HUNG WINDOWS |
| | B) FIXED WINDOW ?? REPLACEMENT FOR |
| | MASTER BEDROOM UNIT |
| | C) CASEMENT WINDOW??? REPLACEMENT FOR |
| | MASTERBEDROOM UNIT |
| | D) MULLIONS |
| | 2B) PRODUCT APPROVALS SUBMITTED WITH |
| | PERMIT APPLICATION AFTER OCTOBER 1, 2003 |
| | ARE REQUIRED TO COMPLY WITH THE FLORIDA |
| | PRODUCT APPROVAL SYSTEM. FOR INFORMATION |
| | PLEASE SEE THE STATE WEBSITE AT |
| | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH |
| | STATEWIDE APPROVAL ARE REQUIRED TO BE |
| | SUBMITTED WITH A COVER SHEET THAT LISTS |
| | THE PRODUCT IDENTITY NUMBER FROM THE |
| | STATE. IF THE PRODUCT DOES NOT HAVE |
| | STATEWIDE APPROVAL, SUBMIT AN APPLICA- |
| | TION FOR LOCAL PRODUCT APPROVAL OR SITE |
| | SPECIFIC FORM PER RULE 9B-72. SEE |
| | ATTACHMENT. WWW.FLORIDABUILDING.ORG |
| | |
| | 3) SLEEPING ROOMS MINIMUM WINDOW SIZE: |
| | 1005.4.4 MINIMUM SIZE. THE MINIMUM NET |
| | CLEAR OPENING HEIGHT DIMENSION SHALL BE |
| | 24 INCHES (610 MM).THE MINIMUM NET |
| | CLEAR OPENING WIDTH DIMENSION SHALL BE |
| | 20 INCHES (508 MM).THE MINIMUM NET |
| | CLEAR OPENING AREA SHALL BE 5.7 SQ FT |
| | (0.53 M^2). SEE ATTACHMENT. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |
| | |
| | |
| | |
| | |