| 2005-11-23 00:00:00 | BUILDING REVIEW CHECKLIST: |
| | 1- PROVIDE FLORIDA PRODUCT APPROVAL OR |
| | APPLY FOR LOCAL PRODUCT APPROVAL FOR |
| | STORM SHUTTERS AS REQUIRED BY RULE 9B-72 |
| | OF DCA AS OF OCT. 1ST 2004. SBCCI REPORT |
| | ALONE IS NOT AUTOMATICALLY AN STATEWIDE |
| | FLORIDA PRODUCT APPROVAL. SEE WEBSITE |
| | WWW.FLORIDABUILDING.ORG FOR MORE PRODUCT |
| | APPROVAL INFO. AND REQUIREMENTS. |
| | |
| | 2- A) UPDATE INSTALLATION SCHEDULE |
| | SHEET. SEE ATTACHED COPY. |
| | B) PROVIDE COMPLETE INFORMATION ON |
| | INSTALLATION SCHEDULE. EG: DESIGN |
| | PRESSURES & SPECIFIC ANCHOR TO BE USED. |
| | C) REVISE INFORMATION WRITTEN ON |
| | INSTALLATION SCHEDULE FORM. SEE CORRECT |
| | SBCCI REPORT. USE UPDATED FORM. IT |
| | SHOULD SAY FLORIDA PRODUCT APPROVAL #. |
| | |
| | 3- ANCHOR SCHEDULE ON SHEET 5 OF 8 OF |
| | STORM PANELS: CIRCLE ONLY THE INFO. THAT |
| | APPLIES TO THIS PROJECT. ALSO, CIRCLE |
| | ANCHOR TYPE AND SPACING ACCORDING TO THE |
| | CORRECT DESIGN PRESSURES. |
| | |
| | 4- STORM PANELS WHICH ARE 115" AND 117" |
| | LONG EXCEED THE MAXIMUM PANEL SPAN |
| | ACCORDING TO TABLE 1 ON SHEET 6 OF 8 OF |
| | STORM PANELS.REVISE AS REQUIRED. |
| | |
| | JULIO GOMEZ |
| | BUILDING PLANS EXAMINER |