| Date |
Text |
| 2006-07-20 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT: 05091455 |
| | ADD: 2995 45TH ST |
| | CONT: B& M CONSTRUCTION |
| | TEL: (954)427-4886 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2ND REVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 2) NEW COMMENT, GLAZED STOREFRONT FROM |
| | THE FIRST REVIEW I ASSUMED JUST THE |
| | GLASS BEING REPLACED WAS NEW. IT APPEARS |
| | |
| | THAT A WHOLE NEW STOREFRONT WILL BE |
| | REPLACED AS OF THE NOTES ON SHEET D-1 & |
| | A-1. |
| | ONE ISSUE IS THAT THE COLUMN LINE ON |
| | THE LEFT SIDE OF THE OPENING KEEPS |
| | SHIFTING. THE DEMO SHEET AND A-1 SHOULD |
| | CORALATE OR SHOW NEW COLUMN AND BEAM TIE |
| | IN.ADDITIONAL INFO REQUIRED. |
| | THE SECOND ISSUE IS WHEN NEW |
| | GLAZINGIS INSTALLED IT WILL NEED TO MEET |
| | |
| | WIND REQUIREMENTS AS WELL AS LARGE |
| | MISSLE IMPACT TESTING. THIS CAN BE MET |
| | BY IMPACT GLAZING AND FRAME OR STORM |
| | SHUTTERS. THE TESTING REPORT SUBMITTED |
| | FOR THE WINDOWS IS FOR WIND ONLY WILL |
| | REQUIRE IMPACT TESTED STORM SHUTTERS AS |
| | WELL. 1609.1.4 PROTECTION OF OPENINGS. |
| | |
| | 3) NEW COMMENT DEALS WITH THE EXISTING |
| | RESTROOMS. NOTE# 3 ON SHEET A-1 |
| | INDICATES NEW VANITY, THIS VANITY STILL |
| | MUST MEET THE REQUIREMENTS OF : |
| | *** 11-4.24.2 SINKS, HEIGHT. SINKS SHALL |
| | BE MOUNTED WITH THE COUNTER NO HIGHER |
| | THAN 34" ABOVE THE FINISH FLOOR. |
| | *** 11-4.24.3 KNEE CLEARANCE THAT IS AT |
| | LEAST 27" HIGH 30" WIDE, AND 19" DEEP |
| | SHALL BE PROVIDED UNDERNEATH SINKS. |
| | |
| | 4) PLUMBING AND ELECTRICAL SHEETS HAVE |
| | THE WRONG SITE ADDRESS. |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | |
| | |