2005-09-28 00:00:00BUILDING REVIEW CHECKLIST:
 1- SELECTED ASSEMBLY SYSTEM IS LIMITED
 BY GENERAL LIMITATION #9 WHICH DOESN'T
 ALLOW FOR NAIL ENHANCING TO UPGRADE THE
 UPIFT CAPACITY AT CORNERS AND PERIMETER
 OF ROOF. CORNER AND PERIMETER AREAS HAVE
 TO WITHSTAND HIGHER UPLIFT LOADS. SEE
 TABLE 1606.2B FBC 2001.
 NEED TO SELECT SYSTEM THAT MEETS THE
 DESIGN PRESSURES SHOWN ON TABLE 1606.2B
 FBC 2001 OR THAT IS LIMITED BY GENERAL
 LIMITATION #7 WHICH ALLOWS ADDITIONAL
 NAIL ENHANCING TO UPGRADE THE DESIGN
 PRESSURES CAPACITY.
  
 2- FLORIDA PRODUCT APPROVAL COVER PAGE
 SUBMITTED SHOWS THAT THE APPLICATION
 STATUS IS PENDING FBC APPROVAL.
 APPLICATION STATUS NEED TO BE APPROVED
 IN ORDER FOR US TO ACCEPT IT. CHECK WITH
 WWW.FLORIDABUILDING.ORG TO SEE IF THE
 STATUS IS ALREADY APPROVED. OTHERWISE,
 MANUFACTURER MAY APPLY FOR LOCAL PRODUCT
 APPROVAL USING THE DADE COUNTY NOA AND
 SUBMITTING A COMPLETE LOCAL PRODUCT
 APPROVAL FORM DOWNLOADED FROM
 WWW.FLORIDABUILDING.ORG
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.