Plan Review Notes
Plan Review Notes For Permit 05091338
Permit Number 05091338
Review Stop B
Sequence Number 1
Notes
Date Text
2005-11-23 00:00:00BUILDING REVIEW CHECKLIST:
 1- ALL OPENINGS HAVE SHUTTERS. NEED TO
 PROVIDE EMERGENCY EGRESS AS REQUIRED BY
 SEC. 1005.4.5 FBC 2001.
  
 2- PROVIDE COMPLETE INSTALLATION
 SCHEDULE. SEE ATTACHED SAMPLE. MODIFY
 SCHEDULE AS REQUIRED TO PROVIDE ALL
 ESSENTIAL INFORMATION FOR EITHER TYPE OF
 SHUTTERS ACCORDION OR PANELS. THIS
 SCHEDULE IS USED FOR PLANS EXAMINER AND
 INSPECTOR AS A CLEAR REFERENCE TO VERIFY
 PANEL SPAN AND ANCHOR TYPE AND SPACING
 FOR PROPER SHUTTERS INSTALLATION.
  
 3- A) ENGINEER'S WIND LOAD CHART NEEDS
 TO HAVE ORIGINAL SEAL & SIGNATURE (BOTH
 COPIES) ANDB) ENGINEER TO PROVIDE ALL
 HIS INFORMATION AS REQUIRED BY CHAPTER
 471 FLORIDA STATUTES WHEN SUBMITTING
 DOCUMENTS FOR PUBLIC RECORDS.
 C) WIND LOAD FORM CHART GENERAL NOTE #7
 SAYS THAT THIS CHART SHALL NOT BE MARKED
 UP. COMPLY WITH ENGINEER'S REQUIREMENT.
  
 4- SHUTTER PRODUCT APPROVAL
 AUTHORIZATION FORM NEED THE JOB ADDRESS
 AND ORIGINAL SIGNATURES TO BE VALID.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712.