| Date |
Text |
| 2008-11-18 16:51:41 | CITY PALMS SUBMITALS/ REVISIONS |
| | PERMIT:05091265 |
| | ADDRESS: 480 HIBISCUS |
| | |
| | ACTION/ DENIED |
| | |
| | SUBMITTAL NO. STEEL STAIR SHOP DRAWINGS AND |
| | CALCULATIONS |
| | |
| | 1) THRESHOLD BUILDING REQUIRING 3 SETS OF ALL DOCUMENTS |
| | SUBMITTED. |
| | |
| | 2) STAIR ELEVATION# 1 LOWER LEFT HAND CORNER, AT THE |
| | INTERMEDIATE LANDING THE HANDRAIL IS NOT CONTINUOUS |
| | PAST THE LAST RISER IN THE UPPER FLIGHT OF |
| | STAIRS.1009.11.4/ 1009.11.5. |
| | 1009.11.4 CONTINUITY. |
| | HANDRAIL-GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT |
| | INTERRUPTION BY NEWEL POSTS OR OTHER OBSTRUCTIONS. |
| | |
| | 1009.11.5 HANDRAIL EXTENSIONS. |
| | HANDRAILS SHALL RETURN TO A WALL, GUARD OR THE WALKING |
| | SURFACE OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN |
| | ADJACENT STAIR FLIGHT. WHERE HANDRAILS ARE NOT |
| | CONTINUOUS BETWEEN FLIGHTS, THE HANDRAILS SHALL EXTEND |
| | HORIZONTALLY AT LEAST 12 INCHES (305 MM) BEYOND THE TOP |
| | RISER AND CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD |
| | BEYOND THE BOTTOM RISER. |
| | |
| | 1012.2 HEIGHT. |
| | GUARDS SHALL FORM A PROTECTIVE BARRIER NOT LESS THAN 42 |
| | INCHES (1067 MM) HIGH, MEASURED VERTICALLY ABOVE THE |
| | LEADING EDGE OF THE TREAD, ADJACENT WALKING SURFACE OR |
| | ADJACENT SEATBOARD. |
| | |
| | |
| | |
| | JIM WITMER C. B. O. |
| | BUILDING PLAN REVIEW II |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)805-6731 |
| | E-MAIL: [email protected] |
| | |
| | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS |
| | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS |
| | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO |
| | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE |
| | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. |