| Plan Review Notes For Permit 05091265 |
| Permit Number |
05091265 |
|
| Review Stop |
B |
| Sequence Number |
32 |
|
| Notes |
| Date |
Text |
| 2007-08-24 17:23:43 | CITY PALMS SUBMITALS/ REVISIONS | | | PERMIT:05091265 | | | ADDRESS: 480 HIBISCUS | | | | | | ACTION: DENIED | | | | | | REVISION NO: SHEET S-7.7 DETAILS 12 & 13 BOTH INDICATE | | | THE USE OF 14 GAUGE TRUSS ANCHORS POURED INTO THE BEAM | | | AT THE EXTERIOR WALL LINE.A SECOND SET OF TRUSS | | | ANCHOR TWISTED STRAPS ARE DEPICTED FUTHER IN ALONG THE | | | BOTTOM CHORD OF THE TRUSS. THESE TRUSS ANCHORS ARE | | | INDICATED TO USE TWISTED STRAPS AND TO USE THREE | | | TAPCONS TO ANCHOR TO THE CONCRETE DECK. THE THREE | | | TAPCONS ARE IN A ROW NOT IN UNISON WHERE THEY WILL TAKE | | | THE LOAD EQUALLY. | | | | | | THE SECOND ISSUE IS THE METAL TRUSS LAYOUT SHEET (SHOP | | | DRAWINGS) SHOWS THE SAME DETAIL REVIEWED BY THE | | | DESIGNER OF RECORD SHOP DRAWING STAMPED WITH | | | EMBEDS AT THE WALL LINE1 PAAIR OF TSWTC5 CLIPS THAT | | | ARE WELDED TO THE EMBEDS, AND THE SECOND SET OF TRUSS | | | ANCHORS BEING TSC2.75 OR TSC4.00 WITH 3 TAPCONS SECURED | | | TO THE CONCRETE DECK TAKING THE LOAD EQUALLY. | | | | | | PLEASE COORDINATE THESE DETAILS SO ONE SYSTEM WILL BE | | | SUBMITTED TO THE BUILDING DEPARTMENT. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|