| Date |
Text |
| 2007-08-07 11:49:17 | CITY PALMS SUBMITALS/ REVISIONS |
| | PERMIT:05091265 |
| | ADDRESS: 480 HIBISCUS |
| | |
| | ACTION: DENIED |
| | |
| | SUBMITTAL NO:TRANSMITTAL# 01465 |
| | REFERENCE: SHIM GAP SLIDING GLASS DOORS |
| | R. C. ALUMINUM SERIES 2400 ST SLIDING GLASS DOORS NOA |
| | 01-0927.05 |
| | THIS PRODUCT APPROVAL STATES: |
| | NOTICE OF ACCEPTANCE: SPECIFIC CONDITIONS |
| | 3. LIMITATIONS |
| | 3.1 THIS APPROVAL APPLIES TO SINGLE UNIT APPLICATIONS, |
| | AS SHOWN APPROVED DRAWINGS. |
| | 4. LIMITATIONS |
| | 4.1 THE ALUMINUM SLIDING GLASS DOOR AND ITS COMPONENTS |
| | SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE |
| | APPROVED DRAWINGS. |
| | |
| | 1) THE TRCHNICAL SHEET 1 OF 6 PROVIDES THE DESIGN LOADS |
| | WITH 1/4", 3/8" AND 1/2" SHIM ROOM, INTO THRESS TYPE OF |
| | SUBSTRATE THRU WOOD BUCKS DIRECTLY INTO MASONRY, |
| | DIRECTLY INTO MASONRY AND INTO METAL STRUCTURES. |
| | |
| | 2) THE PRODUCT APPROVAL WAS TESTED IN STRICT COMPLIANCE |
| | WITH TAS-201, TAS-202 AND TAS-203 THE TEST CRITERIA AND |
| | LIMITATIONS ARE LISTED IN THE PRODUCT APPROVAL AND CAN |
| | NOT BE EXCEEDED. |
| | |
| | 1714.5.2.1 TESTING AND LABELING. |
| | EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN |
| | APPROVED INDEPENDENT TESTING LABORATORY, AND SHALL BE |
| | LABELED WITH AN APPROVED LABEL IDENTIFYING THE |
| | MANUFACTURER, PERFORMANCE CHARACTERISTICS AND APPROVED |
| | PRODUCT CERTIFICATION AGENCY, TESTING LABORATORY, |
| | EVALUATION ENTITY OR MIAMI-DADE PRODUCT APPROVAL TO |
| | INDICATE COMPLIANCE WITH THE REQUIREMENTS OF ONE OF THE |
| | FOLLOWING SPECIFICATIONS: |
| | ANSI/AAMA/NWWDA 101/I.S.2 OR 101/I.S. 2/NAFS OR |
| | AAMA/WDMA/CSA 101/I.S.2/A440 OR TAS 202 (HVHZ SHALL |
| | COMPLY WITH TAS 202 UTILIZING ASTM E 1300 -98 OR ASTM E |
| | 1300-02 OR SECTION 2404 . ) |
| | |
| | BUILDING PLAN REVIEW II |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |