Date Text
2006-03-20 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2001
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2001
  
 1.)PREVIOUS CORRECTION LISTS HAD
 REQUESTED THAT SCOPE OF WORK REGARDING
 THE ROOF BE CLARIFIED.NOW SHEET 1
 STATES THAT THE ROOF IS TO BE PAINTED
 RATHER THAN REPLACED.S1.2 SPECIFIES
 REPLACEMENT OF SHEATHING WHICH IMPLIES
 THAT ROOF WORK WILL BE DONE.THIS
 COMMENT DOES NOT HAVE TO BE ADDRESSED ON
 THE PLAN BUT BE ADVISED THAT PRODUCT
 APPROVALS FOR THE METAL ROOF WILL BE
 REQUIRED UNDER SEPARATE PERMIT.
  
 2.)THE NEW SHEETS T1 AND A9.1 ARE TO
 BE SIGNED, SEALED, AND DATED.
 FAC61G1-16.STATUTORY REQUIREMENTS
 CANNOT BE WAIVED PER BUILDING OFFICIAL.
  
 3.)REMOVE THE REDUCED ARCHITECTURAL
 SHEETS, EXCEPT FOR THE FOOD SERVICE PLAN
 APPROVAL AND ANY OTHER SHEETS WHICH MAY
 HAVE APPROVALS FROM OTHER GOVERNMENTAL
 ENTITIES.
  
 4.)ON ONE OF THE SETS, SOMEONE HAS
 CHANGED THE 2001 FBC TO 2003 FBC.THE
 OTHER PLAN IS STILL 2001 FBC.THIS
 PROJECT COULD BE PERMITTED UNDER EITHER
 FBC2001 OR FBC2004.IT WAS REVIEWED
 UNDER FBC2001.DECLARE GOVERNING CODE.
 CHANGING THE CODE AT THIS POINT WILL
 RESULT IN ADDITIONAL DELAYS.
  
 5.)PRODUCT APPROVALS HAVE BEEN
 REQUESTED TWICE.ONLY WINDOW PRODUCT
 APPROVALS WERE PROVIDED.ALSO REQUIRED
 ARE PRODUCT APPROVALS FOR SIDING, DOORS,
 AND THE METAL ROOF.SEE ALSO COMMENT #1
 ABOVE.
  
 NEW COMMENTS:
  
 6.)A1.1 DECLARES THIS BUILDING AS TYPE
 II CONSTRUCTION, WHICH REQUIRES THAT ALL
 STRUCTURAL ELEMENTS ARE NONCOMBUSTIBLE
 AND MEET THE FIRE RESISTANCE
 REQUIREMENTS OF FBC TABLE 600, FBC604.
 THIS IS IN CONFLICT WITH THE STRUCTURAL
 DETAILS. IN ADDITION TO REQUIRING
 NONCOMBUSTIBLE CONSTRUCTION AND FIRE
 RATING IN COMPLIANCE WITH TABLE 600,
 COMBUSTIBLES IN CONCEALED SPACES ARE NOT
 ALLOWED AND THIS MUST BE NOTED ON THE
 PLAN IF THE BUILDING IS TO BE A TYPE II.
 NOTE THAT THE NEW STRUCTURAL SHOW
 EXTERIOR COMBUSTIBLE NONBEARING WALLS AS
 WELL AS AN EXISTING COMBUSTIBLE ROOF.
 ADDRESS.
  
 7.)WHEN RESUBMITTING, INCLUDE A
 RESPONSE LETTER INDICATING HOW EACH ITEM
 WAS ADDRESSED.